A PEMFC and H2 membrane purification integrated plant

被引:18
作者
Brunetti, Adele [1 ,2 ]
Barbieri, Giuseppe [1 ]
Drioli, Enrico [1 ,2 ]
机构
[1] Univ Calabria, ITM CNR, Inst Membrane Technol, I-87030 Arcavacata Di Rende, CS, Italy
[2] Univ Calabria, Dept Chem & Mat Engn, I-87030 Arcavacata Di Rende, CS, Italy
关键词
membrane-PEMFC integrated plant; pure hydrogen production; PEMFC; efficiencies;
D O I
10.1016/j.cep.2007.03.015
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this work an integrated system composed of a Pd-Ag membrane module and a polymeric electrolyte fuel cell (PEMFC) was studied. The Pd-Ag membrane module, allowing a pure hydrogen permeate stream to be fed directly to the PEMFC, was used as an H-2 Purification step with a mixture containing also CO and CO2. The CO poisoning effect on the Pd-Ag membrane and its consequences on the hydrogen permeation were analysed in a temperature range 300-450 degrees C in terms of permeance reduction conditioning also the H-2 recovery index (RI). A comparison between the experimental data obtained feeding the fuel cell (FC) with pure H-2 from a cylinder and from the purification step was also performed in order to evaluate the PEMFC performance stability. After the experimental study of each single step, particular attention was devoted to the analysis of the integrated system Pd-Ag membrane purification step-PEMFC, focusing on the influence of the Pd-Ag membrane module operating conditions on the electrical performance of the PEMFC. The PEMFC internal crossover was also considered and its effects on the electrical performance were taken into account by means of a PEMFC actual efficiency. Furthermore, integrated membrane plant chemical efficiency was defined considering the H-2 converted into electricity with respect to the total amount of H-2 contained in the mixture. The integrated Pd-Ag membrane purification with PEMFC shows very good results: the hydrogen is well purified and the PEMFC performance is very high near the nominal value. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1081 / 1089
页数:9
相关论文
共 18 条
[1]   Future directions of membrane gas separation technology [J].
Baker, RW .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2002, 41 (06) :1393-1411
[2]   PEM electrolysis for production of hydrogen from renewable energy sources [J].
Barbir, F .
SOLAR ENERGY, 2005, 78 (05) :661-669
[3]   Efficiency and economics of proton exchange membrane (PEM) fuel cells [J].
Barbir, F ;
Gomez, T .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 1996, 21 (10) :891-901
[4]  
Barbir F., 2005, PEM FUEL CELL, P147
[5]   A PEMFC and H2 membrane purification integrated plant [J].
Brunetti, Adele ;
Barbieri, Giuseppe ;
Drioli, Enrico .
DESALINATION, 2006, 199 (1-3) :156-158
[6]   Power output and load following in a fuel cell fueled by membrane reactor hydrogen [J].
Buxbaum, R ;
Lei, HW .
JOURNAL OF POWER SOURCES, 2003, 123 (01) :43-47
[7]   Performance evaluation of an energy recovery system for fuel reforming of PEM fuel cell power plants [J].
Cao, YD ;
Guo, Z .
JOURNAL OF POWER SOURCES, 2002, 109 (02) :287-293
[8]   Theoretical analysis of a pure hydrogen production separation plant for fuel cells dynamical applications [J].
Capobianco, L ;
Del Prete, Z ;
Schiavetti, P ;
Violante, V .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2006, 31 (08) :1079-1090
[9]  
GASTEIGER HA, FUNDAMENTAL RES DEV
[10]   Decline in hydrogen permeation due to concentration polarization and CO hindrance in a palladium membrane reactor [J].
Hara, S ;
Sakaki, K ;
Itoh, N .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (12) :4913-4918