Interface perturbation effects in high-energy electron beams

被引:26
作者
Verhaegen, F
机构
[1] McGill Univ, Montreal Gen Hosp, Dept Med Phys, Montreal, PQ H3G 1A4, Canada
[2] Natl Phys Lab, Ctr Ionising Radiat Metrol, Teddington TW11 0LW, Middx, England
关键词
D O I
10.1088/0031-9155/48/6/301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Near interfaces between two different media exposed to high-energy electron beams substantial dose and fluence perturbations due to backscatter can be observed. In this work, dose and fluence perturbations were studied for 419 MeV electron beams at backscatter interfaces of polystyrene, graphite, water, aluminium and lead. Measurements of relative dose using an NPL-designed thin-window plane-parallel ion chamber and a Markus ion chamber were performed to determine the effect of different interface materials and thicknesses. Results of Monte Carlo simulations with the EGSnrc code, including models of the ion chambers, were found to be in excellent agreement with the measurements. The well-documented increasing dose perturbation with increasing effective atomic number of the backscatter material and decreasing electron beam energy was confirmed. Simulations in a simplified slab geometry showed that, despite the decrease of average electron energy with depth in water, the dose perturbations decrease with increasing depth of the interface in water for all the materials in the study. This was ascribed to the change of the electron angular distribution with depth which has a different effect in water and in the presence of a high-Z interface. Electron fluence perturbations near a lead/water interface were found to cause small differences in unrestricted mass collision stopping power ratios, water to air. Effects of bremsstrahlung photons, characteristic photons and positrons from the backscattering material were found to be insignificant for electron interface dosimetry. When comparing simulations using EGSnrc and the older version of the same code, EGS4, underestimations of the dose perturbation effects of up to 7% were found when using the latter code to simulate 4 MeV electrons irradiating a lead/water interface. It is concluded that EGSnrc is a highly suitable tool for electron interface dosimetry studies.
引用
收藏
页码:687 / 705
页数:19
相关论文
共 34 条
[1]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[2]  
Andreo P, 2000, IAEA TECHNICAL REPOR, V398
[3]  
[Anonymous], 1983, MED PHYS, V10, P741
[4]  
[Anonymous], 2001, PIRS701 NAT RES COUN
[5]   ELECTRON BACKSCATTERING [J].
BAILY, NA .
MEDICAL PHYSICS, 1980, 7 (05) :514-519
[6]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[7]  
BRIESMEISTER JF, 1997, LA12625 LOS AL NAT L
[8]  
BRUN R, 1987, DDEE841 CERN
[9]   A NEW METHOD TO DETERMINE RATIOS OF ELECTRON STOPPING POWERS TO AN IMPROVED ACCURACY [J].
BURNS, DT ;
DUANE, S ;
MCEWEN, MR .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) :733-739
[10]   Mean energy, energy-range relationships and depth-scaling factors for clinical electron beams [J].
Ding, GX ;
Rogers, DWO ;
Mackie, TR .
MEDICAL PHYSICS, 1996, 23 (03) :361-376