Herbert screw fixation of scaphoid fractures

被引:208
作者
Filan, SL [1 ]
Herbert, TJ [1 ]
机构
[1] ST LUKES HOSP, SYDNEY, NSW, AUSTRALIA
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1996年 / 78B卷 / 04期
关键词
D O I
10.1302/0301-620X.78B4.0780519
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We reviewed the records of 431 patients who had open reduction and internal fixation of the scaphoid performed by one surgeon (TJH) over a 13-year period, The Herbert bone screw provided adequate internal fixation without the use of plaster immobilisation, promoting a rapid functional recovery, On average, patients returned to work 4.7 weeks after surgery and wrist function was significantly improved, even when the fracture failed to unite, Healing rates for acute fractures were better than those reported for plaster immobilisation and were independent of fracture location, In the case of established nonunions, healing depended on the stage and location of the fracture, but the progress of arthritis was halted and carpal collapse significantly improved, Internal fixation of the scaphoid using the Herbert bone screw, although technically demanding, has few complications and appears to offer significant advantages over other methods of treatment.
引用
收藏
页码:519 / 529
页数:11
相关论文
共 66 条
[1]   TECHNICAL FACTORS RELATED TO HERBERT SCREW FIXATION [J].
ADAMS, BD ;
BLAIR, WF ;
REAGAN, DS ;
GRUNDBERG, AB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (06) :893-899
[2]   SCAPHOLUNATE ADVANCED COLLAPSE WRIST SALVAGE [J].
ASHMEAD, D ;
WATSON, HK ;
DAMON, C ;
HERBER, S ;
PALY, W .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (05) :741-750
[3]   20TH QUESTIONS ABOUT SCAPHOID FRACTURES [J].
BARTON, NJ .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1992, 17B (03) :289-310
[4]   THE HERBERT SCREW FOR SCAPHOID FRACTURES - A MULTICENTER STUDY [J].
BUNKER, TD ;
MCNAMEE, PB ;
SCOTT, TD .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (04) :631-634
[5]  
CALANDRA JJ, 1992, ORTHOPEDICS, V15, P931
[6]  
CALLANAN I, 1995, P 6 C INT FED SOC SU, P162
[7]   BIOMECHANICAL COMPARISON OF FIXATION DEVICES IN EXPERIMENTAL SCAPHOID OSTEOTOMIES [J].
CARTER, FM ;
ZIMMERMAN, MC ;
DIPAOLA, DM ;
MACKESSY, RP ;
PARSONS, JR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (05) :907-912
[8]   NONUNION OF THE SCAPHOID - ANALYSIS OF THE RESULTS FROM BONE-GRAFTING [J].
COONEY, WP ;
DOBYNS, JH ;
LINSCHEID, RL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1980, 5 (04) :343-354
[9]  
COONEY WP, 1980, CLIN ORTHOP RELAT R, V149, P90
[10]   RETROGRADE HERBERT SCREW FIXATION FOR TREATMENT OF PROXIMAL POLE SCAPHOID NONUNIONS [J].
DEMAAGD, RL ;
ENGBER, WD .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1989, 14A (06) :996-1003