Seven human immunodeficiency virus (HIV) antigen-antibody combination assays: Evaluation of HIV seroconversion sensitivity and subtype detection

被引:69
作者
Ly, TD
Martin, L
Daghfal, D
Sandridge, A
West, D
Bristow, R
Chalouas, L
Qiu, XX
Lou, SC
Hunt, JC
Schochetman, G
Devare, SG
机构
[1] Abbott Labs, AIDS Res & Retrovirus Discovery, Div Diagnost, Abbott Pk, IL 60064 USA
[2] Lab Claude Levy, Ivry, France
[3] Murex Biotech Ltd, Dartford, Kent, England
关键词
D O I
10.1128/JCM.39.9.3122-3128.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
In this study, we evaluated the performance of two prototype human immunodeficiency virus (HIV) antigen-antibody (Ag-Ab) combination assays, one from Abbott Laboratories (AxSYM HIV Ag-Ab) and the other from bioMerieux (VIDAS HIV Duo Ultra), versus five combination assays commercially available in Europe. The assays were Enzygnost HIV Integral, Genscreen Plus HIV Ag-Ab, Murex HIV Ag-Ab Combination, VIDAS HIV Duo, and Vironostika HIV Uniform II Ag-Ab. All assays were evaluated for the ability to detect p24 antigen from HIV-1 groups M and O, antibody-positive plasma samples from HIV-1 groups M and O, HIV-2, and 19 HIV seroconversion panels. Results indicate that although all combination assays can detect antibodies to HIV-1, group M, subtypes A to G, circulating recombinant form (CRF) A/E, and HIV-1 group O, their sensitivity varied considerably when tested using diluted HIV-1 group O and HIV-2 antibody-positive samples. Among combination assays, the AxSYM, Murex, and VIDAS HIV Duo Ultra assays exhibited the best antigen sensitivity (at similar to 25 pg of HIV Ag/ml) for detection of HIV-1 group M, subtypes A to G and CRF A/E, and HIV-1 group O isolates. However, the VIDAS HIV Duo Ultra assay had a lower sensitivity for HIV-1 group M and subtype C, and was unable to detect subtype C antigen even at 125 pg of HIV Ag/ml. The HIV antigen sensitivity of the VIDAS HIV Duo and Genscreen Plus combination assays was similar to 125 pg of HIV Ag/ml for detection of all HIV-1 group M isolates except HIV-1 group O while the sensitivity of Vironostika HIV Uniform II Ag-Ab and Enzygnost BTV Integral Ag-Ab assays for all the group M subtypes was >125 pg of HIV Ag/ml. Among the combination assays, the AxSYM assay had the best performance for detection of early seroconversion samples, followed by the Murex and VIDAS HIV Duo Ultra assays.
引用
收藏
页码:3122 / 3128
页数:7
相关论文
共 26 条
[1]   PERFORMANCE EVALUATION OF THE ABBOTT HTLV-III-EIA, A TEST FOR ANTIBODY TO HTLV-III IN DONOR BLOOD [J].
BARRETT, JE ;
DAWSON, G ;
HELLER, J ;
BAIRSTOW, C ;
FICO, R ;
WEBBER, JS ;
GUTIERREZ, R ;
DECKER, RH .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1986, 86 (02) :180-185
[2]   Serologic and phylogenetic characterization of HIV-1 subtypes in Uganda [J].
Brennan, CA ;
Lund, JK ;
Golden, A ;
Yamaguchi, J ;
Vallari, AS ;
Phillips, JF ;
Kataaha, PK ;
Jackson, JB ;
Devare, SG .
AIDS, 1997, 11 (15) :1823-1832
[3]   Shortening of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1/2/O screening test [J].
Brust, S ;
Duttmann, H ;
Feldner, J ;
Gürtler, L ;
Thorstensson, R ;
Simon, F .
JOURNAL OF VIROLOGICAL METHODS, 2000, 90 (02) :153-165
[4]  
Busch Michael P., 1997, American Journal of Medicine, V102, P117, DOI 10.1016/S0002-9343(97)00077-6
[5]   SCREENING OF SELECTED MALE BLOOD-DONORS FOR P24 ANTIGEN OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 [J].
BUSCH, MP ;
TAYLOR, PE ;
LENES, BA ;
KLEINMAN, SH ;
STUART, M ;
STEVENS, CE ;
TOMASULO, PA ;
ALLAIN, JP ;
HOLLINGSWORTH, CG ;
MOSLEY, JW .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (19) :1308-1312
[6]   DETECTION OF ANTIBODIES TO HUMAN T-CELL LYMPHOTROPIC VIRUS-III (HTLV-III) WITH AN IMMUNOASSAY EMPLOYING A RECOMBINANT ESCHERICHIA-COLI-DERIVED VIRAL ANTIGENIC PEPTIDE [J].
CHANG, TW ;
KATO, I ;
MCKINNEY, S ;
CHANDA, P ;
BARONE, AD ;
WONGSTAAL, F ;
GALLO, RC ;
CHANG, NT .
BIO-TECHNOLOGY, 1985, 3 (10) :905-909
[7]   EFFECTIVENESS OF ASSAYS FOR ANTIBODIES TO HIV AND P24 ANTIGEN TO DETECT VERY RECENT HIV INFECTIONS IN BLOOD-DONORS [J].
COUROUCE, AM ;
BARIN, F ;
MANIEZ, M ;
JANOT, C ;
NOEL, L ;
ELGHOUZZI, MH .
AIDS, 1992, 6 (12) :1548-1550
[8]   BLOOD-TRANSFUSION AND HUMAN IMMUNODEFICIENCY VIRUS (HIV) ANTIGEN [J].
COUROUCE, AM ;
BOUCHARDEAU, F ;
JULLIEN, AM ;
FAUCHER, V ;
LENTZY, M .
ANNALS OF INTERNAL MEDICINE, 1988, 108 (05) :771-772
[9]  
COUROUCE AM, 1994, SPECTRA BIOL, V94, P43
[10]   HTLV-III ENV GENE-PRODUCTS SYNTHESIZED IN ESCHERICHIA-COLI ARE RECOGNIZED BY ANTIBODIES PRESENT IN THE SERA OF AIDS PATIENTS [J].
CROWL, R ;
GANGULY, K ;
GORDON, M ;
CONROY, R ;
SCHABER, M ;
KRAMER, R ;
SHAW, G ;
WONGSTAAL, F ;
REDDY, EP .
CELL, 1985, 41 (03) :979-986