Allocation of supplementary aeration stations in the Chicago waterway system for dissolved oxygen improvement

被引:50
作者
Alp, Emre [1 ]
Melching, Charles S. [2 ]
机构
[1] Middle E Tech Univ, Dept Environm Engn, TR-06531 Ankara, Turkey
[2] Marquette Univ, Dept Civil & Environm Engn, Milwaukee, WI 53201 USA
关键词
In-stream aeration; Dissolved oxygen; Water quality modeling; Watershed management; Use attainability analysis; RIVER; QUALITY;
D O I
10.1016/j.jenvman.2011.01.014
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Chicago Waterway System (CWS), used mainly for commercial and recreational navigation and for urban drainage, is a 122.8 km branching network of navigable waterways controlled by hydraulic structures. The CWS receives pollutant loads from 3 of the largest wastewater treatment plants in the world, nearly 240 gravity Combined Sewer Overflows (CSO), 3 CSO pumping stations, direct diversions from Lake Michigan, and eleven tributary streams or drainage areas. Even though treatment plant effluent concentrations meet the applicable standards and most reaches of the CWS meet the applicable water quality standards, Dissolved Oxygen (DO) standards are not met in the CWS during some periods. A Use Attainability Analysis was initiated to evaluate what water quality standards can be achieved in the CWS. The UAA team identified several DO improvement alternatives including new supplementary aeration stations. Because of the dynamic nature of the CWS, the DUFLOW model that is capable of simulating hydraulics and water quality processes under unsteady-flow conditions was used to evaluate the effectiveness of new supplementary aeration stations. This paper details the use of the DUFLOW model to size and locate supplementary aeration stations. In order to determine the size and location of supplemental aeration stations, 90% compliance with a 5 mg/l DO standard was used as a planning target. The simulations showed that a total of four new supplementary aeration stations with oxygen supply capacities ranging from 30 to 80 g/s would be sufficient to meet the proposed target DO concentration for the North Branch and South Branch of the Chicago River. There are several aeration technologies, two of which are already being used in the CWS, available and the UAA team determined that the total capital costs of the alternatives range from $35.5 to $89.9 million with annual operations and maintenance costs ranging from $554,000 to $2.14 million. Supplemental aeration stations have been shown to be a potentially effective means to improve DO concentrations in the CWS and will be included in developing an integrated strategy for improving water quality in the CWS. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1577 / 1583
页数:7
相关论文
共 33 条
[1]   Effectiveness of combined sewer overflow treatment for dissolved oxygen improvement in the Chicago Waterways [J].
Alp, E. ;
Melching, C. S. ;
Zhang, H. ;
Lanyon, R. .
WATER SCIENCE AND TECHNOLOGY, 2007, 56 (01) :215-222
[2]  
ALP E, 2009, P WORLD ENV WAT RES, P4854
[3]  
Alp E., 2006, Calibration of a model for simulation of water quality during unsteady flow in the Chicago Waterway System and application to evaluate use attainability analysis remedial actions
[4]   Evaluation of the Duration of Storm Effects on In-Stream Water Quality [J].
Alp, Emre ;
Melching, Charles S. .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2009, 135 (02) :107-116
[5]  
AMBERG HR, 1969, TAPPI, V52, P1866
[6]  
[Anonymous], 1988, EPA/600/3-87-039
[7]  
Butts TA, 2000, 200002 ILL STAT WAT
[8]   Water quality control in the river Arno [J].
Campolo, M ;
Andreussi, P ;
Soldati, A .
WATER RESEARCH, 2002, 36 (10) :2673-2680
[9]  
*CTE, 2007, SUPPL AER N S UNPUB
[10]  
Ditoro D.M., 1993, EL932 US ARM ENG WAT, V1, P197