Characteristics associated with low treatment satisfaction in patients with implanted cardioverter defibrillators: Results from the LICAD study

被引:15
作者
Ladwig, KH
Deisenhofer, I
Simon, H
Schmitt, C
Baumert, JJ
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Inst & Poliklin Psychosomat Med Psychotherapie &, D-81675 Munich, Germany
[2] Klin Tech Univ Munchen, Deutsch Herzzentrum Munchen, Munich, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2005年 / 28卷 / 06期
关键词
ICD; treatment satisfaction; anxiety; depression;
D O I
10.1111/j.1540-8159.2005.09509.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The evaluation of low treatment satisfaction (LTS) with on implanted cardioverter defibrillator (ICD) remains a neglected area of clinical research. However, a trustful attitude toward an ICD is crucial. Within the scope of ICD health technology assessment, we searched for predictors of LTS. Of 195 ICD patients enrolled (mean 59.8 years, standard deviation 12.6), 163 (83.6%) were men and 26 (16.4%) were women. We measured anxiety, helplessness, and depression with standardized instruments and LTS with 11 dichotomous items concerning a mistrustful attitude, a negative body image, and low appraisal. A total of 47 (24.1%) patients were considered as LTS patients. Multivariate logistic regression was used for assessment of LTS. Adjusted for age and survey, LTS was significantly more prevalent in depressed, anxious, and phobic patients. Multivariate logistic regression including medical and psychological covariates revealed the experience of > 5 shocks with an odds ratio (OR) of 10.17 (95% CI 3.57-29.00, P < 0.001), being employed with an OR of 8.07 (95% CI 2.39-27.19, P < 0.001), and feelings of helplessness (OR 4.61, 95% CI 1.79-11.90, P < 0.002) as the most important predictors for LTS. Women had a slightly not significant effect on LTS. Age, educational status, and depression were not significant. LTS patients required more support for living with the ICD (P < 0.001). Thus, LTS serves as surrogate measure for deteriorated psychic health. Clinicians should be advised to identify LTS patients and to consider psychotherapeutic counseling for them.
引用
收藏
页码:506 / 513
页数:8
相关论文
共 35 条
[1]  
[Anonymous], DIAGNOSE THERAPIE SO
[2]   THE SOMATOSENSORY AMPLIFICATION SCALE AND ITS RELATIONSHIP TO HYPOCHONDRIASIS [J].
BARSKY, AJ ;
WYSHAK, G ;
KLERMAN, GL .
JOURNAL OF PSYCHIATRIC RESEARCH, 1990, 24 (04) :323-334
[3]   Improved appraisal of the quality of life in patients with automatic implantable cardioverter defibrillator - A psychometric study [J].
Chevalier, P ;
Verrier, P ;
Kirkorian, G ;
Touboul, P ;
Cottraux, J .
PSYCHOTHERAPY AND PSYCHOSOMATICS, 1996, 65 (01) :49-56
[4]   ENRICHING THE DOCTOR-PATIENT-RELATIONSHIP BY INVITING THE PATIENTS PERSPECTIVE [J].
DELBANCO, TL .
ANNALS OF INTERNAL MEDICINE, 1992, 116 (05) :414-418
[5]   Short-term efficacy of a telephone intervention by expert nurses after an implantable cardioverter defibrillator [J].
Dougherty, CM ;
Lewis, FM ;
Thompson, EA ;
Baer, JD ;
Kim, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (12) :1594-1602
[6]   How different from pacemaker patients are recipients of implantable cardioverter-defibrillators with respect to psychosocial adaptation, affective disorders, and quality of life? [J].
Duru, F ;
Büchi, S ;
Klaghofer, R ;
Mattmann, H ;
Sensky, T ;
Buddeberg, C ;
Candinas, R .
HEART, 2001, 85 (04) :375-379
[7]   Comprehensive cardiac rehabilitation programme for implantable cardioverter-defibrillator patients: a randomised controlled trial [J].
Fitchet, A ;
Doherty, PJ ;
Bundy, C ;
Bell, W ;
Fitzpatrick, AP ;
Garratt, CJ .
HEART, 2003, 89 (02) :155-160
[8]  
Franke G., 2002, Die Symptom-Checkliste von Derogatis (SCL-90-R)-Deutsche Version-Manual
[9]   PATIENT SOCIODEMOGRAPHIC CHARACTERISTICS AS PREDICTORS OF SATISFACTION WITH MEDICAL-CARE - A METAANALYSIS [J].
HALL, JA ;
DORNAN, MC .
SOCIAL SCIENCE & MEDICINE, 1990, 30 (07) :811-818
[10]   Psychosocial outcome after ICD implantation: A current perspective [J].
Heller, SS ;
Ormont, MA ;
Lidagoster, L ;
Sciacca, RR ;
Steinberg, JS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (06) :1207-1215