Transduction mechanism of acoustic-wave based chemical and biochemical sensors

被引:64
作者
Lucklum, R [1 ]
Hauptmann, P [1 ]
机构
[1] Otto Von Guericke Univ, IMOS, D-39016 Magdeburg, Germany
关键词
acoustic microsensors; QCM; transmission line model; generalized acoustic load concept;
D O I
10.1088/0957-0233/14/11/002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Acoustic-wave-based sensors are commonly known as mass-sensitive devices. However, acoustic chemical and biochemical sensors also face so-called non-gravimetric effects, especially if they work in a liquid environment. The one-dimensional transmission-line model (TLM) is a powerful tool, which considers the influence of geometric and material properties on the sensor transduction mechanism, most importantly the influence of viscoelastic phenomena. This paper demonstrates the concept of modelling acoustic microsensors on quartz crystal resonators. Particular attention is paid to special cases which allow for simplifications or specific solutions of the TLM, like the acoustic load concept (ALC), the BVD model or the Sauerbrey equation. Deviations from the one-dimensional assumption of the TLM are suspected to significantly contribute to the acoustic sensor response in biosystems. We therefore introduce a generalization of the ALC to get access to two- or three-dimensional effects, which are up to now not considered in the TLM. As examples, signatures of interfacial phenomena or non-uniform films are discussed.
引用
收藏
页码:1854 / 1864
页数:11
相关论文
共 31 条
[1]  
[Anonymous], 1990, ACOUSTIC FIELDS WAVE
[2]  
[Anonymous], 1987, ACOUSTIC WAVES DEVIC
[3]  
Auld B., 1990, ACOUSTIC FIELD WAVES, V1
[4]  
BARTHE PG, 1987, ULTR S P, P697
[5]   The non-gravimetric quartz crystal resonator response and its application for determination of polymer shear modulus [J].
Behling, C ;
Lucklum, R ;
Hauptmann, P .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (11) :1886-1893
[6]   Possibilities and limitations in quantitative determination of polymer shear parameters by TSM resonators [J].
Behling, C ;
Lucklum, R ;
Hauptmann, P .
SENSORS AND ACTUATORS A-PHYSICAL, 1997, 61 (1-3) :260-266
[7]   Is an oscillator-based measurement adequate in a liquid environment? [J].
Borngräber, R ;
Schröder, J ;
Lucklum, R ;
Hauptmann, P .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (09) :1254-1259
[8]  
Cavic BA, 1997, FARADAY DISCUSS, V107, P159
[9]   Influence of surface roughness on the quartz crystal microbalance response in a solution - New configuration for QCM studies [J].
Daikhin, L ;
Urbakh, M .
FARADAY DISCUSSIONS, 1997, 107 :27-38
[10]   Interface circuits for quartz-crystal-microbalance sensors [J].
Eichelbaum, F ;
Borngräber, R ;
Schröder, J ;
Lucklum, R ;
Hauptmann, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (05) :2537-2545