Automated method for targeting analysis of prostanoids in human serum by on-line solid-phase extraction and liquid chromatography-mass spectrometry in selected reaction monitoring

被引:18
作者
Ferreiro-Vera, C. [1 ,2 ]
Mata-Granados, J. M. [1 ,2 ,3 ]
Priego-Capote, F. [1 ,2 ]
Luque de Castro, M. D. [1 ,2 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
[2] Univ Cordoba, Reina Sofia Hosp, Inst Biomed Res Maimonides IMIBIC, E-14071 Cordoba, Spain
[3] Sanyres Grp, Sanyres I D I Dept, E-14012 Cordoba, Spain
关键词
Eicosanoids; Prostanoids; Prostaglandins; Tromboxanes; COX; LC-MS/MS; On-line SPE; ACID; PROSTAGLANDINS; INFLAMMATION; EICOSANOIDS; CYCLOOXYGENASES; ISOPROSTANES; QUANTITATION; CANCER;
D O I
10.1016/j.chroma.2011.03.049
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Prostanoids are potent biologically active lipid molecules demanding for analysis methods combining precision, sensitivity and high-throughput for pharmacological and clinical applications. The present research describes the development and validation of an on-line automated method based on solid-phase extraction liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) for the quantification of prostanoids in human serum. This approach overcomes the main limitation of previous methods involving manual protocols, such as analyte losses, metabolites degradation and time-consuming protocols, are minimized. Human serum (100 mu L) was directly injected into an automatic solid-phase extraction workstation for cleanup and preconcentration of the target metabolites. The eluate was on-line transferred to a reversed-phase analytical column for chromatographic separation prior to mass spectrometry detection in selected reaction monitoring mode. The detection limits for the target analytes ranged from 2.3 to 63.3 pg on column. The precision (expressed as relative standard deviation) was within 3.30 and 6.15% for repeatability and from 4.16 to 11.11% for within-laboratory reproducibility. Accuracy was evaluated with spiked and non-spiked serum samples to estimate concentration differences that could be affected by matrix effects or inefficient SPE performance. Accuracy, estimated as recovery factor, was from 87.7 to 100% for the target compounds. The proposed method is reliable and has an excellent potential for high-throughput use in both clinical and research laboratories by minimizing analyst intervention. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2848 / 2855
页数:8
相关论文
共 27 条
[1]
CAWELLO W, 1994, EUR J CLIN PHARMACOL, V46, P275
[2]
Regulated formation of eicosanoids [J].
Fitzpatrick, FA ;
Soberman, R .
JOURNAL OF CLINICAL INVESTIGATION, 2001, 107 (11) :1347-1351
[3]
Prostaglandins, bioassay and inflammation [J].
Flower, RJ .
BRITISH JOURNAL OF PHARMACOLOGY, 2006, 147 :S182-S192
[4]
GEOFFROY J, 1985, PROSTA LEUKOTR MED, V18, P393, DOI 10.1016/0262-1746(85)90072-1
[5]
Resolution of Adipose Tissue Inflammation [J].
Gonzalez-Periz, Ana ;
Claria, Joan .
THESCIENTIFICWORLDJOURNAL, 2010, 10 :832-856
[6]
Cyclooxygenase-2 generates anti-inflammatory mediators from omega-3 fatty acids [J].
Groeger, Alison L. ;
Cipollina, Chiara ;
Cole, Marsha P. ;
Woodcock, Steven R. ;
Bonacci, Gustavo ;
Rudolph, Tanja K. ;
Rudolph, Volker ;
Freeman, Bruce A. ;
Schopfer, Francisco J. .
NATURE CHEMICAL BIOLOGY, 2010, 6 (06) :433-441
[7]
Arachidonic-acid-derived eicosanoids: roles in biology and immunopathology [J].
Harizi, Hed ;
Corcuff, Jean-Benoit ;
Gualde, Norbert .
TRENDS IN MOLECULAR MEDICINE, 2008, 14 (10) :461-469
[8]
Gamma linolenic acid: An antiinflammatory omega-6 fatty acid [J].
Kapoor, Rakesh ;
Huang, Yung-Sheng .
CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2006, 7 (06) :531-534
[9]
Rapid quantitation of a large scope of eicosanoids in two models of inflammation: Development of an electrospray and tandem mass spectrometry method and application to biological studies [J].
Margalit, A ;
Duffin, KL ;
Isakson, PC .
ANALYTICAL BIOCHEMISTRY, 1996, 235 (01) :73-81
[10]
Lipidomic analysis of twenty-seven prostanoids and isoprostanes by liquid chromatography/electrospray tandem mass spectrometry [J].
Masoodi, Mojgan ;
Nicolaou, Anna .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (20) :3023-3029