Strain fields in histological slices of brain tissue determined by synchrotron radiation-based micro computed tomography

被引:24
作者
Germann, Marco [1 ,2 ,3 ]
Morel, Anne [3 ]
Beckmann, Felix [4 ]
Andronache, Adrian [2 ]
Jeanmonod, Daniel [3 ]
Mueller, Bert [1 ,2 ]
机构
[1] Univ Basel Hosp, Univ Basel, Biomat Sci Ctr, CH-4031 Basel, Switzerland
[2] ETH, Comp Vis Lab, CH-8092 Zurich, Switzerland
[3] Univ Basel, Univ Basel Hosp, Biomat Sci Ctr, CH-8091 Zurich, Switzerland
[4] GKSS Forschungszentrum Geesthacht GmbH, D-21502 Geesthacht, Germany
关键词
brain tissue; 3D visualization; synchrotron radiation; X-ray absorption; image registration; histological strain;
D O I
10.1016/j.jneumeth.2008.01.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Accurate knowledge of the morphology of the human brain is required for minimally or non-invasive surgical interventions. On the (sub-)cellular level, brain tissue is generally characterized using optical microscopy, which allows extracting morphological features with a wide spectrum of staining procedures. The preparation of the histological slices, however, often leads to artifacts resulting in imperfect morphological data. In addition, the generation of 3D data is time-consuming. Therefore, we propose synchrotron radiation-based micro computed tomography (SR mu CT) avoiding preparation artifacts and giving rise to the 3D morphology of features such as gray and white matter on the micrometer level. One can differentiate between white and gray matter without any staining procedure because of different X-ray absorption values. At the photon energy of 10 keV, the white matter exhibits the absorption of 5.08 cm(-1), whereby the value for the gray matter corresponds to 5.25 cm(-1). The tomography data allow quantifying the local strains in the histological images using registration algorithms. The deformation of histological slices compared to the SR mu CT in a 2D-2D registration leads to values of up to 6.3%. Mean deformation values for the Nissl-stained slices are determined to about 1%, whereas the myelin-stained slices yield slightly higher values than 2%. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 36 条
[1]   Non-rigid registration of multi-modal images using both mutual information and cross-correlation [J].
Andronache, A. ;
von Siebenthal, M. ;
Szekely, G. ;
Cattin, Ph. .
MEDICAL IMAGE ANALYSIS, 2008, 12 (01) :3-15
[2]  
ANDRONACHE A, 2006, INFORM TECHNOLOGY EL
[3]   Microtomography using synchrotron radiation as a user experiment at beamlines BW2 and BW5 of HASYLAB at DESY [J].
Beckmann, F .
DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 :34-41
[4]   EXPLANATION OF CEREBRAL WHITE-GRAY CONTRAST IN COMPUTED-TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G ;
KELLER, MR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (04) :489-491
[5]  
Burgel U, 1997, J BRAIN RES, V38, P397
[6]   The creation of a brain atlas for image guided neurosurgery using serial histological data [J].
Chakravarty, MM ;
Bertrand, G ;
Hodge, CP ;
Sadikot, AF ;
Collins, DL .
NEUROIMAGE, 2006, 30 (02) :359-376
[7]   A minimum description length approach to statistical shape modeling [J].
Davies, RH ;
Twining, CJ ;
Cootes, TF ;
Waterton, JC ;
Taylor, CJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (05) :525-537
[8]   Visualization of thalamic nuclei on high resolution, multi-averaged T1 and T2 maps acquired at 1.5 T [J].
Deoni, SCL ;
Josseau, MJC ;
Rutt, BK ;
Peters, TM .
HUMAN BRAIN MAPPING, 2005, 25 (03) :353-359
[9]  
Fatterpekar Girish M, 2003, Magn Reson Imaging Clin N Am, V11, P641, DOI 10.1016/S1064-9689(03)00071-0
[10]   OPTIMUM ENERGIES FOR X-RAY TRANSMISSION TOMOGRAPHY OF SMALL SAMPLES - APPLICATIONS OF SYNCHROTRON RADIATION TO COMPUTERIZED-TOMOGRAPHY .1. [J].
GRODZINS, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03) :541-545