In line measurement of chemical oxygen demand by means of multipulse amperometry at a rotating Pt ring -: Pt/PbO2 disc electrode

被引:76
作者
Westbroek, P [1 ]
Temmerman, E [1 ]
机构
[1] State Univ Ghent, Dept Analyt Chem, B-9000 Ghent, Belgium
关键词
ring-disc; cyclic voltammetry; double potential step; COD;
D O I
10.1016/S0003-2670(01)00927-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper an amperometric method that makes use of a the rotating ring-disc electrode (RRDE) configuration is described for the determination of the chemical oxygen demand (COD). It is shown that the strong oxidant necessary in COD measurements can be generated by an electrolytic in situ formation of an aggressive species, at the disc part of the ring-disc electrode, that oxidises the compounds that contribute to the GOD. The excess of aggressive species formed reacts further to oxygen, which is determined at the ring electrode. Compensation of the disc current signal for the ring current signal finally results into the COD value of the solution. In this paper the COD value of real samples from a textile and a photo developing company were analysed and it was shown that a precision of 1% could be obtained within the range of 20-25,000 mg l(-1). An important advantage is the fact that the COD value of a solution of unknown composition can be obtained within 1 min after calibration of the electrode system. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:95 / 105
页数:11
相关论文
共 26 条
[1]  
APPLETON JMH, 1986, ANAL CHIM ACTA, V179, P269, DOI 10.1016/S0003-2670(00)84471-2
[2]   CHEMICAL OXYGEN-DEMAND DETERMINATION IN WELL AND RIVER WATERS BY FLOW-INJECTION ANALYSIS USING A MICROWAVE-OVEN DURING THE OXIDATION STEP [J].
BALCONI, ML ;
BORGARELLO, M ;
FERRAROLI, R ;
REALINI, F .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :295-299
[3]   DETERMINATION OF CHEMICAL OXYGEN-DEMAND OF WASTEWATERS WITHOUT THE USE OF MERCURY SALTS [J].
BALLINGER, D ;
LLOYD, A ;
MORRISH, A .
ANALYST, 1982, 107 (1278) :1047-1053
[4]   EFFECT OF INORGANIC CONSTITUENTS ON CHEMICAL OXYGEN-DEMAND .2. ORGANIC-CARBON TO HALOGEN RATIOS DETERMINE HALOGEN INTERFERENCE [J].
BELKIN, S ;
BRENNER, A ;
ABELIOVICH, A .
WATER RESEARCH, 1992, 26 (12) :1583-1588
[5]  
Bilanovic D, 1997, WATER SA, V23, P301
[6]   Water quality monitoring using a smart sensing system [J].
Charef, A ;
Ghauch, A ;
Baussand, P ;
Martin-Bouyer, M .
MEASUREMENT, 2000, 28 (03) :219-224
[7]   Development of highly sensitive BOD sensor and its evaluation using preozonation [J].
Chee, GJ ;
Nomura, Y ;
Ikebukuro, K ;
Karube, I .
ANALYTICA CHIMICA ACTA, 1999, 394 (01) :65-71
[8]  
F'errari AE, 1998, AFINIDAD, V55, P341
[9]   DETERMINATION OF LOW CHEMICAL OXYGEN-DEMAND VALUES IN WATER BY THE DICHROMATE SEMI-MICRO METHOD [J].
HEJZLAR, J ;
KOPACEK, J .
ANALYST, 1990, 115 (11) :1463-1467
[10]   THE DETERMINATION OF CHEMICAL OXYGEN-DEMAND IN WASTEWATERS WITH DICHROMATE BY FLOW-INJECTION ANALYSIS [J].
KORENAGA, T ;
IKATSU, H .
ANALYTICA CHIMICA ACTA, 1982, 141 (SEP) :301-309