Numerical analysis and laboratory testing of seed spacing uniformity performance for vacuum-cylinder precision seeder

被引:109
作者
Zhao Zhan [1 ,2 ]
Li Yaoming [1 ]
Chen Jin [2 ]
Xu Lizhang [1 ]
机构
[1] Jiangsu Univ, Minist Educ & Jiangsu Prov, Key Lab Modern Agr Equipment & Technol, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Jiangsu Univ, Sch Mech Engn, Zhenjiang 212013, Jiangsu, Peoples R China
基金
高等学校博士学科点专项科研基金;
关键词
OPTOELECTRONIC SENSOR SYSTEM;
D O I
10.1016/j.biosystemseng.2010.02.012
中图分类号
S2 [农业工程];
学科分类号
082806 [农业信息与电气工程];
摘要
The performance of a vacuum-cylinder seeder for the precision sowing of rape seeds was investigated. For releasing seeds from nozzles smoothly, a positive differential pressure was applied to the seed. The forces acting on the seeds in free flight were calculated using the computational fluid dynamics (CFD) software Fluent. Using the differential equation for seed motion, seeds falling trajectories using different working parameters were numerically determined. A high-speed camera system mounted on a laboratory seeder test-rig was used to record the motion of seeds. A mean shift algorithm for tracking seeds was used. The horizontal displacement x and the fall time t(f) of seeds predicted by the numerical analysis and measured by the high-speed camera system were compared. The results indicated that the relative errors of x and t(f) were < 5.5% and 6.5%, respectively, indicating good agreement. Based on the analysis of seeds falling trajectories, it was found that the variations of positive differential pressure Delta p and release angle theta had significant effects on seeding uniformity. In order to analyse their effects on horizontal displacement, a coefficient of positive differential pressure variation chi(p) and coefficient of sowing angle variation chi(theta) were proposed and their values calculated. Calculations indicated that the optimum levels for Delta p and theta for the precision seeding of rape seeds were in the range of 1-2 kPa and from -10 to 0 degrees, respectively. Experiments were carried out on the vacuum-cylinder precision seeder test-rig and the results showed that the average seed spacing interval error reached the minimum at Delta p = 1.5 kPa and theta = -5 degrees and that the error increased almost linearly with increasing of cylinder rotational speed. (c) 2010 IAgrE. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:344 / 351
页数:8
相关论文
共 10 条
[1]
Laboratory measurement of seed drill seed spacing and velocity of fall of seeds using high-speed camera system [J].
Karayel, D ;
Wiesehoff, M ;
Özmerzi, A ;
Müller, J .
COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2006, 50 (02) :89-96
[2]
Mathematical modelling of vacuum pressure on a precision seeder [J].
Karayel, D ;
Barut, ZB ;
Özmerzi, A .
BIOSYSTEMS ENGINEERING, 2004, 87 (04) :437-444
[3]
Kocher MF, 1998, T ASAE, V41, P237, DOI 10.13031/2013.17143
[4]
Opto-electronic sensor system for laboratory measurement of planter seed spacing with small seeds [J].
Lan, Y ;
Kocher, MF ;
Smith, JA .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1999, 72 (02) :119-127
[5]
Li YaoMing Li YaoMing, 2008, Nongye Jixie Xuebao = Transactions of the Chinese Society for Agricultural Machinery, V39, P95
[6]
Özmerzi A, 2002, BIOSYST ENG, V82, P227, DOI [10.1006/bioe.2002.0057, 10.1006/beng.2002.0057]
[7]
Panning JW, 2000, APPL ENG AGRIC, V16, P7
[8]
Optimisation of design and operational parameters of a pneumatic seed metering device for planting cottonseeds [J].
Singh, RC ;
Singh, G ;
Saraswat, DC .
BIOSYSTEMS ENGINEERING, 2005, 92 (04) :429-438
[9]
Optimisation of the seed spacing uniformity performance of a vacuum-type precision seeder using response surface methodology [J].
Yazgi, Arzu ;
Degirmencioglu, Adnan .
BIOSYSTEMS ENGINEERING, 2007, 97 (03) :347-356
[10]
ZHAO Z, 2008, INT C INF AUT EL AGR, P504