Redox voltammetry of sub-parts per billion levels of Cu2+ at polyaspartate-modified gold electrodes

被引:77
作者
Yang, WR [1 ]
Gooding, JJ [1 ]
Hibbert, DB [1 ]
机构
[1] Univ New S Wales, Sch Chem, Sydney, NSW 2052, Australia
关键词
D O I
10.1039/b102898g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical sensor for the detection of Cu2+ is reported which incorporates poly-l-aspartic acid (PLAsp) with 32-96 aspartate units as a selective ligand for the metal ion, PLAsp is covalently attached to a gold electrode modified with a monolayer of 3-mercaptopropionic acid using carbodiimide coupling via an N-hydroxysuccinimide (NHS) ester intermediate. The acid side groups and deprotonated peptide nitrogens on two aspartate moieties are thought to be primarily responsible for chelation of Cu2+, which remains bound when reduced to Cu+. A consequence of the multiple binding points that are available with a polypeptide is the low detection limit. The lowest concentration detected was 3 nM (0.2 ppb) achieved with Osteryoung square wave voltammetry. This detection limit compares favourably with that of ICP-OES and previously reported cysteine-modified electrodes. Analysis of tap and lake water samples using the PLAsp-modified electrode agreed well with ICP-OES analysis of the same samples.
引用
收藏
页码:1573 / 1577
页数:5
相关论文
共 47 条
[1]  
Alexander PW, 1998, ELECTROANAL, V10, P707, DOI 10.1002/(SICI)1521-4109(199808)10:10<707::AID-ELAN707>3.0.CO
[2]  
2-V
[3]   Apparent enhanced underpotential voltammetry of lead(II) at a spontaneously adsorbed monolayer-coated gold electrode [J].
Arrigan, DWM ;
Le Bihan, L ;
Pickup, MJ .
ANALYST, 1999, 124 (12) :1797-1802
[4]   A study of L-cysteine adsorption on gold via electrochemical desorption and copper(II) ion complexation [J].
Arrigan, DWM ;
Le Bihan, L .
ANALYST, 1999, 124 (11) :1645-1649
[5]  
Australian and New Zealand Environment and Conservation Council/Australian Water Resources Council, 1992, NAT WAT QUAL MAN STR
[6]   Potentiometric stripping analysis of copper using cysteine modified mercury film electrode [J].
Bai, Y ;
Ruan, XY ;
Mo, JY ;
Xie, YQ .
ANALYTICA CHIMICA ACTA, 1998, 373 (01) :39-46
[7]   Trace determination of mercury by anodic stripping voltammetry at the rotating gold electrode [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 2000, 424 (01) :65-76
[8]  
CHECHIK V, 2000, ADV MAT WEINHEIM, V121, P1161
[9]   Multivariate curve resolution of cyclic voltammetric data:: Application to the study of the cadmium-binding properties of glutathione [J].
Díaz-Cruz, MS ;
Mendieta, J ;
Tauler, R ;
Esteban, M .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4629-4636
[10]   Zinc-binding properties of the C-terminal hexapeptide Lys-Cys-Thr-Cys-Cys-Ala from mouse metallothionein:: Analysis by differential pulse polarography and multivariate curve resolution [J].
Díaz-Cruz, MS ;
Mendieta, J ;
Monjonell, A ;
Tauler, R ;
Esteban, M .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :353-363