Prospective comparison of 3-dimensional volume rendered computerized tomography and conventional renal arteriography for surgical planning in patients undergoing laparoscopic donor nephrectomy

被引:54
作者
Abou El Fettouh, H
Herts, BR
Nimeh, T
Wirth, SL
Caplin, A
Sands, M
Ramani, AP
Kaouk, J
Goldfarb, DA
Gill, IS
机构
[1] Cleveland Clin Fdn, Inst Urol, Sect Laparoscop & Minimally Invas Surg, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Inst Urol, Sect Renal Transplantat, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
关键词
kidney; nephrectomy; tomography; x-ray computed; angiography; laparoscopy;
D O I
10.1097/01.ju.0000068039.79654.d3
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We prospectively assessed the accuracy of 3-dimensional (3-D) volume rendered computerized tomography (CT) and conventional renal arteriography to visualize renovascular anatomy in patients undergoing laparoscopic donor nephrectomy. Materials and Methods: A total of 60 consecutive patients undergoing laparoscopic donor nephrectomy (left side in 46 and right side in 14) prospectively underwent 3-D CT and renal angiography. A short videotape of 3-D CT was prepared using volume rendering software that demonstrated the anatomical location, number, anomalies and spatial interrelationships of the renal arteries and veins. These 3-D videotapes and arteriogram findings were directly correlated with intraoperative surgical findings at laparoscopy and during ex vivo bench preparation of the harvested kidney. The perceived intraoperative value of 3D-CT to delineate renovascular anatomical detail was scored subjectively by the laparoscopic surgeon for each case on a 10-point scale of 0-completely inaccurate to 10-completely accurate. Results: There were no complications related to the 3-D CT protocol and volume rendering was successful in all patients. Three-D CT accurately identified the number of renal arteries in 59 patients (98%). In I patient with 3 renal arteries 3-D CT and arteriogram each identified only 2. In the 46 patients undergoing left donor nephrectomy 3-D CT accurately identified the number of veins and venous anomalies in 45 (98%), including 2 with a circumaortic left renal vein. Another case of circumaortic vein was misdiagnosed as 2 renal veins. On the right side in 14 patients 3-D CT accurately identified the renal veins in 13 (94%) and missed 1 vein in a patient with 2 renal veins. Angiography correctly identified the number of renal veins in only 52 cases (87%). Furthermore, it misdiagnosed all 3 cases of circumaortic left renal vein. The laparoscopic surgeon believed that 3-D CT accurately identified the location and anatomical interrelationship of the renal vessels with precision. Mean subjective score +/- SEM was 8.5 +/- 1 for the arterial system, 8.6 +/- 1.1 for the venous system and 9.2 +/- 0.5 for any vascular anomalies. Conclusions: Three-D CT accurately identifies renal vascular anatomy in a manner that may facilitate renal hilar dissection during laparoscopic donor nephrectomy, especially during the initial surgeon experience. This imaging modality integrates essential information from angiography, venography and excretory urography into a single study, and it can obviate the need for more invasive vascular imaging in most cases.
引用
收藏
页码:57 / 60
页数:4
相关论文
共 15 条
[1]   3-dimensional volume rendered computerized tomography for preoperative evaluation and intraoperative treatment of patients undergoing nephron sparing surgery [J].
Coll, DM ;
Uzzo, RG ;
Herts, BR ;
Davros, WJ ;
Wirth, SL ;
Novick, AC .
JOURNAL OF UROLOGY, 1999, 161 (04) :1097-1102
[2]   3-DIMENSIONAL IMAGING [J].
FISHMAN, EK ;
MAGID, D ;
NEY, DR ;
CHANEY, EL ;
PIZER, SM ;
ROSENMAN, JG ;
LEVIN, DN ;
VANNIER, MW ;
KUHLMAN, JE ;
ROBERTSON, DD .
RADIOLOGY, 1991, 181 (02) :321-337
[3]   RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY [J].
GALANSKI, M ;
PROKOP, M ;
CHAVAN, A ;
SCHAEFER, CM ;
JANDELEIT, K ;
NISCHELSKY, JE .
RADIOLOGY, 1993, 189 (01) :185-192
[4]   SPIRAL(HELICAL) CT [J].
HEIKEN, JP ;
BRINK, JA ;
VANNIER, MW .
RADIOLOGY, 1993, 189 (03) :647-656
[5]   Triphasic helical CT of the kidneys: Contribution of vascular phase scanning in patients before urologic surgery [J].
Herts, BR ;
Coll, DM ;
Lieber, ML ;
Streem, SB ;
Novick, AC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (05) :1273-1277
[6]  
Jacobs SC, 2000, J UROLOGY, V164, P1494, DOI 10.1016/S0022-5347(05)67014-0
[7]   CT ANGIOGRAPHY WITH VOLUME RENDERING - IMAGING FINDINGS [J].
KUSZYK, BS ;
HEATH, DG ;
NEY, DR ;
BLUEMKE, DA ;
URBAN, BA ;
CHAMBERS, TP ;
FISHMAN, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :445-448
[8]   Potential renal donors: Comparison of conventional imaging with helical CT [J].
Platt, JF ;
Ellis, JH ;
Korobkin, M ;
Reige, KA ;
Konnak, JW ;
Leichtman, AB .
RADIOLOGY, 1996, 198 (02) :419-423
[9]  
RATNER LE, 1995, TRANSPLANTATION, V60, P1047
[10]  
RUBIN GD, 1995, RADIOL CLIN N AM, V33, P51