Development and evaluation of an HPLC-DAD method for determination of synthetic food colorants

被引:57
作者
Kirschbaum, J [1 ]
Krause, C [1 ]
Pfalzgraf, S [1 ]
Brückner, H [1 ]
机构
[1] Univ Giessen, Interdisciplinary Res Ctr, Inst Nutr Sci, Dept Food Sci, D-35392 Giessen, Germany
关键词
column liquid chromatography; diode-array detection; food colorant analysis; synthetic food colorants;
D O I
10.1007/BF02492092
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
As a result of recent European Union regulations food colorants must be determined quantitatively, not just qualitatively as in the past. We demonstrate that a mixture of 14 synthetic food colorants (E 102, E 104, E 110, E 122, E 123, E 124, E 127 E 128, E 129, E 131, E 132, E 133, E 142, and E 151) can best be resolved by use of a Purospher RP18e column (125 mm x 4 mm i.c., 5 mum particle) and a gradient prepared from 100 mm acetate buffer (pH 70) and acetonitrile. Diode-array detection was used to monitor the colorants; limits of detection ranged from 0.02 ng (E 142) to 2.05 ng (E 132) at a signal-to-noise ratio of 3.
引用
收藏
页码:S115 / S119
页数:5
相关论文
共 30 条
[1]  
Berzas Nevado J. J., 1999, Analytica Chimica Acta, V378, P63, DOI 10.1016/S0003-2670(98)00574-1
[2]  
Berzas-Nevado JJ, 1998, ANAL LETT, V31, P2513
[3]   Simultaneous determination of sunset yellow and Ponceau 4R in gelatin powder by derivative spectrophotometry and partial least-squares multivariate spectrophotometric calibration [J].
Bozdogan, A ;
Özgür, MÜ ;
Koyuncu, I .
ANALYTICAL LETTERS, 2000, 33 (14) :2975-2982
[4]   Simultaneous determination of the colorants tartrazine, ponceau 4R and sunset yellow FCF in foodstuffs by solid phase spectrophotometry using partial least squares multivariate calibration [J].
Capitan-Vallvey, LF ;
Fernandez, MD ;
de Orbe, I ;
Avidad, R .
TALANTA, 1998, 47 (04) :861-868
[5]   Simultaneous determination of the colorants sunset yellow FCF and quinoline yellow by solid-phase spectrophotometry using partial least squares multivariate calibration [J].
CapitanVallvey, LF ;
Fernandez, MD ;
deOrbe, I ;
Vilchez, JL ;
Avidad, R .
ANALYST, 1997, 122 (04) :351-354
[6]   SEPARATION OF SYNTHETIC DYES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON 3-MU-M COLUMNS [J].
CHAYTOR, JP ;
HEAL, RL .
JOURNAL OF CHROMATOGRAPHY, 1986, 368 (02) :450-455
[7]   Determination of eight synthetic food colorants in drinks by high-performance ion chromatography [J].
Chen, QC ;
Mou, SF ;
Hou, XP ;
Riviello, JM ;
Ni, ZM .
JOURNAL OF CHROMATOGRAPHY A, 1998, 827 (01) :73-81
[8]   Quantitative analysis of synthetic dyes in lipstick by micellar electrokinetic capillary chromatography [J].
Desiderio, C ;
Marra, C ;
Fanali, S .
ELECTROPHORESIS, 1998, 19 (8-9) :1478-1483
[9]  
*DFG, 1988, FARBST KOMM COL FOOD
[10]  
FREDE W, 1978, DEUT LEBENSM-RUNDSCH, V74, P363