Determination of ticagrelor and two metabolites in plasma samples by liquid chromatography and mass spectrometry

被引:96
作者
Sillen, Henrik [1 ]
Cook, Melanie [2 ]
Davis, Patty [3 ]
机构
[1] AstraZeneca R&D, Molndal, Sweden
[2] York Bioanalyt Solut, York, N Yorkshire, England
[3] AstraZeneca, Wilmington, DE USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 25期
关键词
Ticagrelor; AZD6140; P2Y(12) receptor inhibitor; Platelets; Incurred sample reproducibility; Incurred sample stability; P2Y(12) RECEPTOR ANTAGONIST; ACUTE CORONARY SYNDROMES; CLOPIDOGREL; AZD6140; THROMBOSIS; PRASUGREL; SAFETY; TRIAL;
D O I
10.1016/j.jchromb.2010.06.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rapid and sensitive analytical methods using liquid chromatography with tandem mass spectrometry (LC/MS/MS) were developed for the determination of ticagrelor, the first reversible oral platelet P2Y(12) receptor inhibitor, and its metabolites AR-C124910XX and AR-C133913XX in human plasma. Ticagrelor and its metabolites were extracted using protein precipitation with acetonitrile. Chromatographic separations were performed on reversed phase columns and detection using atmospheric pressure chemical ionization (APCI). Ticagrelor and AR-C124910XX were analyzed in the same assay, with the internal standard, d7-ZD6140, on a C18 column using negative ionization; AR-C133913XX analyzed separately on a phenyl column using positive ionization. Full validation of the methods was performed including selectivity, lower limit of quantification, accuracy, precision stability and incurred sample reproducibility and incurred sample stability. Total analytical run time was short (2 min). Calibration curves were established in the range 5-5000 ng/mL for ticagrelor, 2.5-2500 ng/mL for AR-C124910XX and 2-1000 ng/mL for AR-C133913XX. Lower limits of quantification for ticagrelor, AR-C124910XX and AR-C133913XX were determined to be 5, 2.5 and 2.0 ng/mL, respectively from 100 mu L of human plasma. For ticagrelor, AR-C124910XX and AR-C133913XX, mean intra-batch accuracy was 91.9-109.0%, 86.8-109.2% and 100.5-112.0%, respectively; intra-batch precision was 4.0-8.4%, 5.2-16.9% and 3.9-12.3%, respectively. The methods were also applied to quantification of ticagrelor, AR-C124910XX and AR-C133913XX in rabbit, rat, mouse and marmoset, using 25111 of animal plasma. A modified methodology was developed to quantify ticagrelor and AR-C124910XX in plasma from dog and cynomolgus monkey. Human incurred samples were found to generate consistent reproducibility and stability results. This method was successfully applied to determine plasma concentrations following administration of ticagrelor in human volunteers and patients, and animal safety evaluation studies. This validated methods has the advantages of being straightforward, robust and allows a fast throughput of samples. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2299 / 2306
页数:8
相关论文
共 14 条
[1]  
BUTLER K, ABSORPTION DIS UNPUB
[2]   Safety, tolerability, and initial efficacy of AZD6140, the first reversivle oral adenosine diphosphate receptor antagonist, compared with clopidigrel, in patients with non-ST-segment elevation acute coronary syndrome - Primary results of the DISPERSE-2 trial [J].
Cannon, Christopher P. ;
Husted, Steen ;
Harrington, Robert A. ;
Scirica, Benjamin M. ;
Emanuelsson, Hakan ;
Storey, Robert F. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (19) :1844-1851
[3]   Determination of the active and inactive metabolites of prasugrel in human plasma by liquid chromatography/tandem mass spectrometry [J].
Farid, Nagy A. ;
McIntosh, Mary ;
Garofolo, Fabio ;
Wong, Ernest ;
Shwajch, Amanda ;
Kennedy, Monika ;
Young, Michelle ;
Sarkar, Pratibha ;
Kawabata, Kiyoshi ;
Takahashi, Makoto ;
Pang, Henrianna .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (02) :169-179
[4]   Pharmacodynamics, pharmacokinetics, and safety of the oral reversible P2Y12 antagonist AZD6140 with aspirin in patients with atherosclerosis:: a double-blind comparison to clopidogrel with aspirin [J].
Husted, S ;
Emanuelsson, H ;
Heptinstall, S ;
Sandset, PM ;
Wickens, M ;
Peters, G .
EUROPEAN HEART JOURNAL, 2006, 27 (09) :1038-1047
[5]   Comparison of ticagrelor, the first reversible oral P2Y12 receptor antagonist, with clopidogrel in patients with acute coronary syndromes: Rationale, design, and baseline characteristics of the PLATelet inhibition and patient Outcomes (PLATO) trial [J].
James, Stefan ;
Akerblom, Axel ;
Cannon, Christopher P. ;
Emanuelsson, Hakan ;
Husted, Steen ;
Katus, Hugo ;
Skene, Allan ;
Steg, Philippe Gabriel ;
Storey, Robert F. ;
Harrington, Robert ;
Becker, Richard ;
Wallentin, Lars .
AMERICAN HEART JOURNAL, 2009, 157 (04) :599-605
[6]   Determination of clopidogrel in human plasma by liquid chromatography/tandem mass spectrometry: application to a clinical pharmacokinetic study [J].
Shin, Beom Soo ;
Yoo, Sun Dong .
BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (09) :883-889
[7]   From ATP to AZD6140:: The discovery of an orally active reversible P2Y12 receptor antagonist for the prevention of thrombosis [J].
Springthorpe, Brian ;
Bailey, Andrew ;
Barton, Patrick ;
Birkinshaw, Timothy N. ;
Bonnert, Roger V. ;
Brown, Roger C. ;
Chapman, David ;
Dixon, John ;
Guile, Simon D. ;
Humphries, Robert G. ;
Hunt, Simon F. ;
Ince, Francis ;
Ingall, Anthony H. ;
Kirk, Ian P. ;
Leeson, Paul D. ;
Leff, Paul ;
Lewis, Richard J. ;
Martin, Barrie P. ;
McGinnity, Dermot F. ;
Mortimore, Michael P. ;
Paine, Stuart W. ;
Pairaudeau, Garry ;
Patel, Anil ;
Rigby, Aaron J. ;
Riley, Robert J. ;
Teobald, Barry J. ;
Tomlinson, Wendy ;
Webborn, Peter J. H. ;
Willis, Paul A. .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2007, 17 (21) :6013-6018
[8]   Quantitative determination of clopidogrel active metabolite in human plasma by LC-MS/MS [J].
Takahashi, Makoto ;
Pang, Henrianna ;
Kawabata, Kiyoshi ;
Farid, Nagy A. ;
Kurihara, Atsushi .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (04) :1219-1224
[9]  
US FDA, 2001, GUID IND BIOAN METH
[10]  
VAN GIEZEN JJJ, 2005, SEMIN THROMB HEMOST, V31, P195