Biomechanics of Grade I degenerative lumbar spondylolisthesis.: Part 2:: Treatment with threaded interbody cages/dowels and pedicle screws

被引:25
作者
Çagli, S [1 ]
Crawford, NR [1 ]
Sonntag, VKH [1 ]
Dickman, CA [1 ]
机构
[1] St Josephs Hosp, Barrow Neurol Inst, Div Neurol Surg, Spinal Biomech Res Lab, Phoenix, AZ USA
关键词
degenerative spondylolisthesis; anterior lumbar interbody fusion; threaded interbody cages; biomechanics;
D O I
10.3171/spi.2001.94.1.0051
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. The authors sought to determine the biomechanical effectiveness of threaded interbody cages or dowels compared with that achieved using pedicle screw instrumentation in resisting Grade I lumbar spine degenerative spondylolisthesis. Methods. Thirty-three levels obtained from seven cadaveric lumbar spines were instrumented with cages or dowels, pedicle screw/rod instrumentation, or both. Entire specimens were loaded with nonconstraining torques. Each level was loaded with anteroposterior shear forces while an optical system was used to measure the specimen's motion at individual levels. Pedicle screw/rods outperformed interbody cages and dowels in treating spondylolisthesis. Cages or dowels alone provided only moderate biomechanical stability, and their effectiveness depended heavily on the integrity of the ligaments and remaining annulus, whereas the success of pedicle screw fixation relied predominantly on the integrity of the bone for solid fixation. Little biomechanical difference was demonstrated between cages and dowels; both devices were susceptible to loosening with cyclic fatigue. Conclusions. Biomechanically, cages or dowels alone were suboptimal for treating lumbar spondylolisthesis, especially compared with pedicle screw/rods. Threaded cages or dowels used together with pedicle screws/rods created the most stable construct.
引用
收藏
页码:51 / 60
页数:10
相关论文
共 15 条
[1]
Biomechanics of Grade I degenerative lumbar spondylolisthesis.: Part 1:: In vitro model [J].
Crawford, NR ;
Çagli, S ;
Sonntag, VKH ;
Dickman, CA .
JOURNAL OF NEUROSURGERY, 2001, 94 (01) :45-50
[2]
TRANSPEDICULAR SCREW-ROD FIXATION OF THE LUMBAR SPINE - OPERATIVE TECHNIQUE AND OUTCOME IN 104 CASES [J].
DICKMAN, CA ;
FESSLER, RG ;
MACMILLAN, M ;
HAID, RW .
JOURNAL OF NEUROSURGERY, 1992, 77 (06) :860-870
[3]
EMERY SE, 1999, SEMIN SPINE SURG, V11, P34
[4]
Jost B, 1998, Eur Spine J, V7, P132
[5]
Interbody cage stabilisation in the lumbar spine - Evaluation of cage design, posterior instrumentation and bone density [J].
Lund, T ;
Oxland, TR ;
Jost, B ;
Cripton, P ;
Grassmann, S ;
Etter, C ;
Nolte, LP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :351-359
[6]
MAIMAN DJ, 1996, NEUROLOGICAL SURG, P2221
[7]
DEGENERATIVE LUMBAR SPONDYLOLISTHESIS - A METAANALYSIS OF LITERATURE 1970-1993 [J].
MARDJETKO, SM ;
CONNOLLY, PJ ;
SHOTT, S .
SPINE, 1994, 19 (20) :S2256-S2265
[8]
Efficacy of pedicle screw fixation in the treatment of spinal instability and failed back surgery: a 5-year review [J].
Masferrer, R ;
Gomez, CH ;
Karahalios, DH ;
Sonntag, VKH .
JOURNAL OF NEUROSURGERY, 1998, 89 (03) :371-377
[9]
Threaded fusion cage for lumbar spondylolisthesis [J].
Mizuno, J ;
Nakagawa, H .
NEUROLOGIA MEDICO-CHIRURGICA, 1998, 38 (03) :155-160
[10]
Nibu K, 1997, J SPINAL DISORD, V10, P357