Thermo-economic-environmental multiobjective optimization of a gas turbine power plant with preheater using evolutionary algorithm

被引:157
作者
Avval, H. Barzegar [2 ]
Ahmadi, P. [1 ]
Ghaffarizadeh, A. R. [3 ]
Saidi, M. H. [1 ]
机构
[1] Sharif Univ Technol, Sch Mech Engn, Ctr Excellence Energy Convers, Tehran, Iran
[2] Energy Optimizat Res & Dev Grp, Tehran, Iran
[3] Azad Univ Arak, Dept Comp Sci, Arak, Iran
关键词
multiobjective optimization; gas turbine plant; exergy analysis; thermoeconomics; thermal modeling; exergy destruction; genetic algorithm; THERMODYNAMIC ANALYSIS; EXERGY ANALYSIS; CYCLE; SYSTEM;
D O I
10.1002/er.1696
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, the gas turbine power plant with preheater is modeled and the simulation results are compared with one of the gas turbine power plants in Iran namely Yazd Gas Turbine. Moreover, multiobjective optimization has been performed to find the best design variables. The design parameters of the present study are selected as: air compressor pressure ratio (r(AC)), compressor isentropic efficiency (eta(AC)), gas turbine isentropic efficiency (eta(GT)), combustion chamber inlet temperature (T-3) and gas turbine inlet temperature. In the optimization approach, the exergetic, economic and environmental aspects have been considered. In multiobjective optimization, the three objective functions, including the gas turbine exergy efficiency, total cost rate of the system production including cost rate of environmental impact and CO2 emission, have been considered. The thermoenvironomic objective function is minimized while power plant exergy efficiency is maximized using a genetic algorithm. To have a good insight into this study, a sensitivity analysis of the results to the interest rate as well as fuel cost has been performed. In addition, the results showed that at the lower exergetic efficiency in which the weight of thermoenvironomic objective is higher, the sensitivity of the optimal solutions to the fuel cost is much higher than the location of Pareto Frontier with the lower weight of thermoenvironomic objective. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:389 / 403
页数:15
相关论文
共 40 条
[1]  
AHMADI P, 2008, P ASME SUMM HEAT TRA
[2]  
AHMADI P, 2006, THESIS POWER WATER U
[3]   Energy and exergy analysis of a steam power plant in Jordan [J].
Aijundi, Isam H. .
APPLIED THERMAL ENGINEERING, 2009, 29 (2-3) :324-328
[4]   Exergy analysis of a 420 MW combined cycle power plant [J].
Ameri, M. ;
Ahmadi, P. ;
Khanmohammadi, S. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (02) :175-183
[5]  
Ameri M., 2007, P 15 INT C MECH ENG
[6]   The study of ambient temperature effects on exergy losses of a heat Recovery Steam Generator [J].
Ameri, Mohammad ;
Ahmadi, Pourya .
CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, :55-+
[7]   Energy, exergy and exergoeconomic analysis of a steam power plant: A case study [J].
Ameri, Mohammad ;
Ahmadi, Pouria ;
Hamidi, Armita .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (05) :499-512
[8]  
[Anonymous], P 16 INT C MECH ENG
[9]  
[Anonymous], THESIS SHIRAZ U TECH
[10]  
AVVAL HB, 2007, P 1 IR THERM C ISF I