Vectorcardiographic loop alignment and morphologic beat-to-beat variability

被引:57
作者
Sornmo, L
机构
[1] Lund Univ, Dept Appl Elect, S-221 Lund, Sweden
[2] Lund Univ, Dept Clin Physiol, S-221 Lund, Sweden
关键词
loop alignment; maximum-likelihood (ML) estimation; morphologic QRS variability; vectorcardiogram;
D O I
10.1109/10.730434
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The measurement of subtle morphologic beat-to-beat variations in the electrocardiogram is complicated by the presence of respiration-induced movements of the heart. A statistical signal model is developed which accounts for such movements by means of scaling, rotation, and time synchronization of vectorcardiographic loops. The maximum-likelihood estimator of the parameters describing these three transformations is presented and is extended to the case of multiple loop alignment. The performance of the method is assessed by measuring morphologic variability before and after loop alignment. It is shown that the effects of respiration on morphologic variability can be considerably reduced by the new method. Measurements on morphologic variability were typically reduced by a factor of 0.53 after loop alignment. The results show also that beat-to-beat measurements are strongly dependent on the selected sampling rate and that a rate of 1 kHz is too low.
引用
收藏
页码:1401 / 1413
页数:13
相关论文
共 25 条
[1]  
ALSTE J, 1986, COMPUT BIOMED RES, V19, P417
[2]   Maximum likelihood analysis of cardiac late potentials [J].
Atarius, R ;
Sornmo, L .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (01) :60-68
[3]   BEAT-TO-BEAT ELECTROCARDIOGRAPHIC MORPHOLOGY VARIATION IN HEALED MYOCARDIAL-INFARCTION [J].
BENHAIM, SA ;
BECKER, B ;
EDOUTE, Y ;
KOCHANOVSKI, M ;
AZARIA, O ;
KAPLINSKY, E ;
PALTI, Y .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (08) :725-728
[4]  
FAYN J, 1990, THESIS I NATL SCI AP
[5]  
FAYN J, 1986, COMPUT CARDIOL, P533
[6]   INFLUENCE OF RESPIRATION ON RECORDING CARDIAC POTENTIALS - ISOPOTENTIAL SURFACE-MAPPING AND VECTORCARDIOGRAPHIC STUDIES [J].
FLAHERTY, JT ;
BLUMENSC.SD ;
ALEXANDE.AW ;
GENTZLER, RD ;
GALLIE, TM ;
BOINEAU, JP ;
SPACH, MS .
AMERICAN JOURNAL OF CARDIOLOGY, 1967, 20 (01) :21-&
[7]  
Golub GH, 1989, MATRIX COMPUTATIONS
[8]  
KESTLER H, 1996, COMPUTERS CARDIOLOGY
[9]   ELECTROCARDIOGRAM SIGNAL VARIANCE ANALYSIS IN THE DIAGNOSIS OF CORONARY-ARTERY DISEASE - A COMPARISON WITH EXERCISE STRESS TEST IN AN ANGIOGRAPHICALLY DOCUMENTED HIGH PREVALENCE POPULATION [J].
NOWAK, J ;
HAGERMAN, I ;
YLEN, M ;
NYQUIST, O ;
SYLVEN, C .
CLINICAL CARDIOLOGY, 1993, 16 (09) :671-682
[10]   THE EFFECT OF RESPIRATION-INDUCED HEART MOVEMENTS ON THE ECG [J].
PALLASARENY, R ;
COLOMINASBALAGUE, J ;
ROSELL, FJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (06) :585-590