Impact of gamma sterilization on clinical performance of polyethylene in the knee

被引:202
作者
Collier, JP
Sperling, DK
Currier, JH
Sutula, LC
Saum, KA
Mayor, MB
机构
[1] Dartmouth Biomedical Engineering Center, Thayer School of Engineering, Dartmouth College, Hanover, NH
[2] DePuy DuPont Orthopaedics, Newark, DE
[3] Dartmouth-Hitchcock Medical Center, Lebanon, NH
[4] Dartmouth Biomedical Engineering Center, Thayer School of Engineering, Dartmouth College, Hanover, NH 03755-8000
关键词
polyethylene; ultrahigh-molecular-weight polyethylene; oxidation; gamma sterilization; knee prosthesis;
D O I
10.1016/S0883-5403(96)80026-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Damage and rapid wear of the ultrahigh-molecular-weight polyethylene bearings of knee components continue to be major sources of failure of knee pros theses. Despite considerable research into the roles of design, polyethylene thickness and quality, and component alignment, the source of the rapid wear failures has remained a mystery. This study documents elevated oxidation resulting from the use of gamma sterilization in air, the most common sterilization technique used by the orthopaedic implant industry This oxidation reduces static strength and elongation properties and significantly decreases the resistance of polyethylene bearings to fatigue, a frequent source of early damage of many of these devices.
引用
收藏
页码:377 / 389
页数:13
相关论文
共 22 条
[1]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[2]   THE EFFECT OF STERILIZING RADIATION ON THE PROPERTIES OF ULTRAHIGH MOLECULAR-WEIGHT POLYETHYLENE [J].
BIRKINSHAW, C ;
BUGGY, M ;
WHITE, JJ .
MATERIALS CHEMISTRY AND PHYSICS, 1986, 14 (06) :549-558
[3]   MECHANISM OF AGING IN IRRADIATED POLYMERS [J].
BIRKINSHAW, C ;
BUGGY, M ;
DALY, S ;
ONEILL, M .
POLYMER DEGRADATION AND STABILITY, 1988, 22 (03) :285-294
[4]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, V273, P232
[5]  
Hines WilliamH., 1990, Probability and Statistics in Engineering and Management Science
[6]   RETRIEVAL ANALYSIS OF TOTAL KNEE PROSTHESES - A METHOD AND ITS APPLICATION TO 48 TOTAL CONDYLAR PROSTHESES [J].
HOOD, RW ;
WRIGHT, TM ;
BURSTEIN, AH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (05) :829-842
[7]  
KURTH M, 1987, 45 ANN TECHN C SOC P
[8]  
Landy M M, 1988, J Arthroplasty, V3 Suppl, pS73, DOI 10.1016/S0883-5403(88)80013-5
[9]   ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE - THE MATERIAL AND ITS USE IN TOTAL JOINT IMPLANTS [J].
LI, S ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (07) :1080-1090
[10]  
MCNAMARA JL, 1994, CLIN ORTHOP RELAT R, V299, P104