Fabrication of poly(methyl methacrylate) microfluidic chips by redox-initiated polymerization

被引:21
作者
Chen, Jiang
Lin, Yuehe
Chen, Gang
机构
[1] Fudan Univ, Sch Pharm, Shanghai 200433, Peoples R China
[2] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
CE; microchip; miniaturization; poly(methyl methacrylate); redox-initiated polymerization;
D O I
10.1002/elps.200700071
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
in this report, a method based on the redox-initiated polymerization of methyl methacrylate (MMA) has been developed for the rapid fabrication of poly(methyl methacrylate) (PMMA) microfluidic chips. MMA containing 2-2'-azo-bis-isobutyronitrile was allowed to pre-polymerize in a water bath to form a viscous prepolymer solution that was subsequently mixed with MMA containing a redox-initiation couple of benzoyl peroxide/ N, N-dimethylaniline. The dense molding solution was sandwiched between a silicon template and a piece of 1-mm-thick PMMA plate. The polymerization could complete within 50 min under ambient temperature. The images of raised microfluidic structures on the silicon template were precisely replicated into the synthesized PMMA substrate during the redox-initiated polymerization of the molding solution. The chips were subsequently assembled by the thermal bonding of the channel plates and the covers. The new fabrication approach obviates the need for special equipment and significantly simplifies the process of fabricating PMMA microdevices. The attractive performance of the novel PMMA microchips has been demonstrated in connection with contactless conductivity detection for the separation and detection of ionic species.
引用
收藏
页码:2897 / 2903
页数:7
相关论文
共 28 条
  • [1] Micro total analysis systems. 2. Analytical standard operations and applications
    Auroux, PA
    Iossifidis, D
    Reyes, DR
    Manz, A
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (12) : 2637 - 2652
  • [2] Bayer H, 1996, J MICROCOLUMN SEP, V8, P479
  • [3] Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO
  • [4] 2-7
  • [5] Polymer microfluidic devices
    Becker, H
    Locascio, LE
    [J]. TALANTA, 2002, 56 (02) : 267 - 287
  • [6] CAI G, 2001, UP TO DATE HDB REFER, P81
  • [7] Monitoring environmental pollutants by microchip capillary electrophoresis with electrochemical detection
    Chen, G
    Lin, YH
    Wang, J
    [J]. TALANTA, 2006, 68 (03) : 497 - 503
  • [8] Low temperature bonding of poly(methylmethacrylate) electrophoresis microchips by in situ polymerisation
    Chen, G
    Li, JH
    Qu, S
    Chen, D
    Yang, PY
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1094 (1-2) : 138 - 147
  • [9] Electrophoresis microchips with sharp inlet tips, for contactless conductivity detection, fabricated by in-situ surface polymerization
    Chen, Y
    Yang, PY
    Li, JH
    Chen, D
    Chen, G
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (03) : 683 - 691
  • [10] Fabrication and characterization of poly(methyl methacrylate) microchannels by in situ polymerization with a novel metal template
    Chen, ZF
    Gao, YH
    Su, RG
    Li, CW
    Lin, JM
    [J]. ELECTROPHORESIS, 2003, 24 (18) : 3246 - 3252