Reproducibility of intravascular ultrasound and intracoronary Doppler measurements

被引:12
作者
Gaster, AL
Korsholm, L
Thayssen, P
Pedersen, KE
Haghfelt, TH
机构
[1] Odense Univ Hosp, Dept Cardiol, DK-5000 Odense, Denmark
[2] Odense Univ, Dept Stat & Demog, Odense, Denmark
关键词
intravascular ultrasound; intracoronary Doppler; reproducibility;
D O I
10.1002/ccd.1202
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to evaluate the reproducibility of intravascular ultrasound (IVUS) and intracoronary (IC) Doppler flow velocity measurements. The use of IVUS and IC Doppler has been suggested as a means for percutaneous coronary intervention (PCI) guidance in a series of studies. This would require an acceptable level of accuracy and reproducibility of these two methods for lesion evaluation. In this study, the main focus was on the issue of reproducibility. One hundred and eight patients referred for PCI entered into the study. Inter- and intraobserver variability was measured. Catheter difference was assessed. On-line and off-line measurements were compared. MUSIC criteria were assessed off-line, twice. Calculated and measured diameters were compared. After having obtained initial IC Doppler measurements, the Doppler wire was immediately withdrawn and repositioned for reacquisition of Doppler measurements. IVUS measurements are reproducible and reliable off-line and, to a slightly lesser degree, on-line. Area measurements should be performed more than once and the mean used for vessel description. Lumen diameters should be calculated from the mean of the area measurements. A measuring technique consensus should be reached and adhered to. CFR measurements can be used to determine reduced vs. normal flow reserve. In this study, it was found that proximal to distal velocity ratio and diastolic to systolic velocity ratio variability made these parameters unsuitable for PCI guidance. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:449 / 458
页数:10
相关论文
共 38 条
[1]  
Aengevaeren WRM, 1998, CATHETER CARDIO DIAG, V45, P16, DOI 10.1002/(SICI)1097-0304(199809)45:1<16::AID-CCD4>3.0.CO
[2]  
2-9
[3]  
Albertini A, 1999, BIOELECTROMAGNETICS, V20, P372, DOI 10.1002/(SICI)1521-186X(199909)20:6<372::AID-BEM6>3.0.CO
[4]  
2-L
[5]  
Apostol JC, 2000, J AM COLL CARDIOL, V35, p45A
[6]   INTRACORONARY 2-DIMENSIONAL ULTRASOUND IMAGING IN THE ASSESSMENT OF PLAQUE MORPHOLOGIC FEATURES AND THE PLANNING OF CORONARY INTERVENTIONS [J].
BAPTISTA, J ;
DIMARIO, C ;
ESCANED, J ;
ARNESE, M ;
OZAKI, Y ;
DEFEYTER, P ;
ROELANDT, JRTC ;
SERRUYS, PW .
AMERICAN HEART JOURNAL, 1995, 129 (01) :177-187
[7]   Comparison of exercise electrocardiography and dobutamine echocardiography with invasively assessed myocardial fractional flow reserve in evaluation of severity of coronary arterial narrowing [J].
Bartunek, J ;
VanSchuerbeeck, E ;
deBruyne, B .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (04) :478-&
[8]   Improved assessment of coronary stenosis severity using the relative flow velocity reserve [J].
Baumgart, D ;
Haude, M ;
Goerge, G ;
Ge, JB ;
Vetter, S ;
Dagres, N ;
Heusch, G ;
Erbel, R .
CIRCULATION, 1998, 98 (01) :40-46
[9]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[10]   Intravascular ultrasound and stent implantation:: Intraobserver and interobserver variability [J].
Blessing, E ;
Hausmann, D ;
Sturm, M ;
Wolpers, HG ;
Amende, I ;
Mügge, A .
AMERICAN HEART JOURNAL, 1999, 137 (02) :368-371