Improved outcomes in the recent management of secondary aortoenteric fistula

被引:98
作者
Armstrong, PA [1 ]
Back, MR [1 ]
Wilson, JS [1 ]
Shames, ML [1 ]
Johnson, BL [1 ]
Bandyk, DF [1 ]
机构
[1] Univ S Florida, Coll Med, Div Vasc & Endovasc Surg, Tampa, FL 33606 USA
关键词
D O I
10.1016/j.jvs.2005.06.020
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: We reviewed the presentation, management, and late events in a recent experience with aortic graft-enteric communications (secondary aortoenteric fistula) to identify variables associated with poor outcomes. Methods. Since 1991, 29 patients (19 men, 10 women; mean age, 70) presented with a secondary aortoenteric fistula. The duration from aortic graft implantation to aortoenteric fistula development ranged from 8 months to 180 months (mean, 47 months). Presenting symptoms included gastrointestinal bleeding (n = 25), sepsis and retroperitoneal abscess (n = 3), and ruptured para-anastomotic aneurysm (n = 1). One third (10/29) of patients were hypotensive at presentation. Repair was accomplished by graft excision with axillobifemoral bypass (17 simultaneous, 8 staged), graft excision with in situ deep vein replacement (n = 2), or graft excision with rifampin-treated prosthetic replacement (n = 2). Mean follow-up was 51 months, and the incidence of late events was reported by life table methods. Results: The operative (<= 30-day) mortality rate was 21%, with shock at presentation (P < .01), the need for preoperative transfusion (P < .01), and use of suprarenal aortic clamping during aortoenteric fistula repair (P = .03) associated with lethal outcome. Cumulative mortality related to aortoenteric fistula management was only 24% within an overall 5-year survival rate of 61%. Freedom from recurrent infection or amputation was 86% and 88% at 5 years, respectively, and assisted graft patency was 79%. Presence of staphylococcal species in 22% of patients and occasional operative findings of adjacent perigraft "biofilm" suggests that underlying indolent graft infection may contribute to the development of aortoenteric fistula in some cases. Conclusion: Outcomes associated with aortoenteric fistula repair were surprisingly favorable in the absence of preoperative hemodynamic instability.
引用
收藏
页码:660 / 666
页数:7
相关论文
共 18 条
  • [1] BANDYK DF, 1984, ARCH SURG-CHICAGO, V119, P102
  • [2] Expanded application of in situ replacement for prosthetic graft infection
    Bandyk, DF
    Novotney, ML
    Back, MR
    Johnson, BL
    Schmacht, DC
    [J]. JOURNAL OF VASCULAR SURGERY, 2001, 34 (03) : 411 - 419
  • [3] Chuter TAM, 2000, J ENDOVASC THER, V7, P240, DOI 10.1583/1545-1550(2000)007<0240:EROAPA>2.3.CO
  • [4] 2
  • [5] Autogenous aortoiliac/femoral reconstruction from superficial femoral-popliteal veins: Feasibility and durability
    Clagett, GP
    Valentine, RJ
    Hagino, RT
    [J]. JOURNAL OF VASCULAR SURGERY, 1997, 25 (02) : 255 - 266
  • [6] In situ replacement of infected aortic grafts with rifampicin-bonded prostheses: The Leicester experience (1992 to 1998)
    Hayes, PD
    Nasim, A
    London, NJM
    Sayers, RD
    Barrie, WW
    Bell, PRF
    Naylor, AR
    [J]. JOURNAL OF VASCULAR SURGERY, 1999, 30 (01) : 92 - 98
  • [7] Allograft replacement for infrarenal aortic graft infection:: Early and late results in 179 patients
    Kieffer, E
    Gomes, D
    Chiche, L
    Fléron, MH
    Koskas, F
    Bahnini, A
    [J]. JOURNAL OF VASCULAR SURGERY, 2004, 39 (05) : 1009 - 1017
  • [8] SECONDARY AORTOENTERIC FISTULA - CONTEMPORARY OUTCOME WITH USE OF EXTRAANATOMIC BYPASS AND INFECTED GRAFT EXCISION
    KUESTNER, LM
    REILLY, LM
    JICHA, DL
    EHRENFELD, WK
    GOLDSTONE, J
    STONEY, RJ
    [J]. JOURNAL OF VASCULAR SURGERY, 1995, 21 (02) : 184 - 196
  • [9] LORENTZEN JE, 1985, SURGERY, V98, P81
  • [10] AUTOGENOUS RECONSTRUCTION WITH THE LOWER-EXTREMITY DEEP VEINS - AN ALTERNATIVE TREATMENT OF PROSTHETIC INFECTION AFTER RECONSTRUCTIVE SURGERY FOR AORTOILIAC DISEASE
    NEVELSTEEN, A
    LACROIX, H
    SUY, R
    [J]. JOURNAL OF VASCULAR SURGERY, 1995, 22 (02) : 129 - 134