Development of an integrated CAD-FEA process for below-knee prosthetic sockets

被引:39
作者
Goh, JCH
Lee, RS
Toh, SL
Ooi, CK
机构
[1] Natl Univ Singapore, Dept Orthopaed Surg, Singapore 119260, Singapore
[2] Natl Univ Singapore, Div Bioengn, Singapore 119260, Singapore
[3] DSO, Defence Med & Environm Res Inst, Singapore 117510, Singapore
关键词
computer-aided design; finite element analysis; rehabilitation; lower limb prosthesis; interface pressure; socket fit; pressure distribution; validation procedure;
D O I
10.1016/j.clinbiomech.2005.02.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Background. Computer-aided design and manufacturing has been successfully used in prosthetic applications since 1980s. It simplifies the socket rectification process and improves reproducibility but does not introduce any new principle into socket design. Integrating finite element analysis to CAD will provide a more objective assessment of socket fit and improve the chance of a successful first fitting. Methods. Current study aims to establish a finite element model generation technique directly from geometrical information of commercial prosthetic CAD workstation. A program developed in-house automatically performs meshing of the stump geometry and assigns suitable material properties, load and boundary conditions to the model. The model was validated by comparing predicted pressure with experimentally measured values for one amputee subject. Findings. The predicted pressure distribution has an root-mean-square error of 8.8 kPa compared to experimental values at 10%, 25% and 50% of the gait cycle. Interpretation. Current method was able to develop a finite element model to predict interface pressure reasonably well and can be integrated with prosthetic CAD system to provide quantitative feedback to the prosthetist in an automated process. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:623 / 629
页数:7
相关论文
共 24 条
[1]
Appoldt F, 1968, J Biomech, V1, P247, DOI 10.1016/0021-9290(68)90020-1
[2]
BENNET LB, 1973, B PROSTHET RES, V10, P103
[3]
BERESCHOT G, 1988, ISPO WORKSH CAD CAM
[4]
Brennan J.M., 1991, ADV BIOENG, V20, P547
[5]
Static and dynamic pressure profiles of a patellar-tendon-bearing (PTB) socket [J].
Goh, JCH ;
Lee, PVS ;
Chong, SY .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2003, 217 (H2) :121-126
[6]
Krouskop T A, 1987, J Rehabil Res Dev, V24, P31
[7]
LEE AJC, 1992, RECENT ADVANCES IN COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING, P1
[8]
Lee EA, 2000, J MICROBIOL BIOTECHN, V10, P415
[9]
LEE VS, 1995, P 8 WORLD C ISPO, P127
[10]
Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees - A preliminary study [J].
Lee, VSP ;
Solomonidis, SE ;
Spence, WD .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (02) :167-180