dc link voltage control of UPQC for better dynamic performance

被引:23
作者
Axente, Iurie [1 ]
Basu, Malabika [1 ]
Conlon, Michael F. [1 ]
机构
[1] Dublin Inst Technol, Sch Elect Engn Syst, Dublin 8, Ireland
关键词
Unified Power Quality Conditioner; Power quality conditioning; dc link voltage control; POWER QUALITY IMPROVEMENT;
D O I
10.1016/j.epsr.2011.05.005
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The dc link voltage of the Unified Power Quality Conditioner (UPQC) can significantly deviate from its reference during a transient event, caused by load connection/disconnection or/and supply side voltage sag/swell, though in the steady state the average dc link voltage is maintained at a certain preset level. During such transients, due to considerable dc link voltage deviation, the magnitude of the series injected voltage cannot be constant and this has an effect on the load voltage magnitude, which fluctuates. An improved sinusoidal pulse width modulation (PWM) voltage controller for the series compensator is proposed which adjusts continuously the amplitude modulation ratio in response to the dc link voltage deviations. Also, an adaptive dc link voltage controller is proposed which limits the dc link voltage deviation during transients and assures a negligible steady-state error. The effectiveness of the proposed control schemes is demonstrated through simulations. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1815 / 1824
页数:10
相关论文
共 11 条
[1]   TRENDS IN ACTIVE POWER-LINE CONDITIONERS [J].
AKAGI, H .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1994, 9 (03) :263-268
[2]  
Akagi H, 2007, INSTANTANEOUS POWER
[3]   A 12-kVA DSP-Controlled Laboratory Prototype UPQC Capable of Mitigating Unbalance in Source Voltage and Load Current [J].
Axente, Iurie ;
Ganesh, Jayanti Navilgone ;
Basu, Malabika ;
Conlon, Michael F. ;
Gaughan, Kevin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (06) :1471-1479
[4]   Investigation on the performance of UPQC-Q for voltage sag mitigation and power quality improvement at a critical load point [J].
Basu, M. ;
Das, S. P. ;
Dubey, G. K. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2008, 2 (03) :414-423
[5]   Comparative evaluation of two models of UPQC for suitable interface to enhance power quality [J].
Basu, Malabika ;
Das, Shyama P. ;
Dubey, Gopal K. .
ELECTRIC POWER SYSTEMS RESEARCH, 2007, 77 (07) :821-830
[6]  
Dutton K., 1997, The art of control engineering
[7]   The unified power quality conditioner: The integration of series- and shunt-active filters [J].
Fujita, H ;
Akagi, H .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1998, 13 (02) :315-322
[8]  
Ghosh A., 2002, POWER QUALITY ENHANC
[9]   Fuzzy logic controlled shunt active power filter for power quality improvement [J].
Jain, SK ;
Agrawal, P ;
Gupta, HO .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2002, 149 (05) :317-328
[10]  
Mohan N., 1995, Power Electronics: Converters, Applications, and Design