Interpretation of TCD Spectral Patterns Detected During Carotid Artery Stent Interventions

被引:10
作者
Jeong, Hye Seon [1 ]
Song, Hee-Jung [1 ]
Lee, Jae-Hwan [2 ,3 ]
Choi, Si Wan [2 ,3 ]
Kim, Jei [1 ]
机构
[1] Chungnam Natl Univ Hosp, Dept Neurol, Taejon 301721, South Korea
[2] Chungnam Natl Univ Hosp, Dept Internal Med, Taejon 301721, South Korea
[3] Coll Med, Taejon, South Korea
关键词
carotid artery stent; transcranial Doppler monitoring; high-intensity transient signals; microemboli; collateralization; diffusion weighted magnetic resonance imaging; HIGH-RISK PATIENTS; M-MODE DOPPLER; TRANSCRANIAL DOPPLER; ENDARTERECTOMY; ANGIOPLASTY; STENOSIS; EMBOLI; LESIONS;
D O I
10.1583/11-3400.1
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
Purpose: To classify transcranial Doppler (TCD) spectral patterns and analyze the significance of the patterns in the determination of hemodynamic alterations occurring during filter-protected carotid artery stent (CAS) procedures. Methods: Data on middle cerebral artery (MCA) monitoring and post-CAS diffusion weighted magnetic resonance imaging (DWMRI) were reviewed for 53 patients (45 men; mean age 67.6 +/- 8.3 years) who underwent TCD evaluation before CAS and TCD monitoring during the procedure. TCD spectral patterns were classified according to the hemodynamic changes that occurred after different portions of the CAS procedures. The relationships among the spectral patterns and the frequency and location of new DWMRI lesions were analyzed. Results: TCD spectral changes were classified into 4 patterns: (1) microemboli signals (53, 100%), (2) right-left collateral signals (31/53, 58%), (3) spectral suppression after balloon inflation (31/44, 70%), and (4) continuous spectral suppression after balloon removal (4/44, 9%). Even though microembolic signals were frequently observed during CAS, the new DWMRI lesions were more frequently observed outside of the cerebral territory (78%) rather than in the territory ipsilateral to CAS (47%). The presence of right-left collaterals was related to less severe balloon-related spectral suppression on ipsilateral MCA (p < 0.05). Continuous spectral suppression appeared after stent deployment and balloon dilation and was immediately reversed after removal of the filter device. Conclusion: The spectral patterns classified in the present study may prove useful in anticipating CAS procedure-related hemodynamic alterations. Close hemodynamic observation using these spectral patterns could be helpful in preventing serious complications during CAS. J Endovasc Ther. 2011; 18: 518-526
引用
收藏
页码:518 / 526
页数:9
相关论文
共 24 条
[1]
What should we do with asymptomatic carotid stenosis? [J].
Abbott, Anne L. ;
Bladin, Christopher F. ;
Levi, Christopher R. ;
Chambers, Brian R. .
INTERNATIONAL JOURNAL OF STROKE, 2007, 2 (01) :27-39
[2]
Prediction of early cerebral outcome by transcranial Doppler monitoring in carotid bifurcation angioplasty and stenting [J].
Ackerstaff, RGA ;
Suttorp, MJ ;
van den Berg, JC ;
Overtoom, TTC ;
Vos, JA ;
Bal, ET ;
Zanen, P .
JOURNAL OF VASCULAR SURGERY, 2005, 41 (04) :618-624
[3]
Ackerstaff RGA, 2006, FRONT NEUROL NEUROSC, V21, P229, DOI 10.1159/000092435
[4]
INTRAOPERATIVE TRANSCRANIAL DOPPLER - LIMITATIONS OF THE METHOD [J].
BASS, A ;
KRUPSKI, WC ;
SCHNEIDER, PA ;
OTIS, SM ;
DILLEY, RB ;
BERNSTEIN, EF .
JOURNAL OF VASCULAR SURGERY, 1989, 10 (05) :549-553
[5]
Silent embolism in diagnostic cerebral angiography and neurointerventional procedures: a prospective study [J].
Bendszus, M ;
Koltzenburg, M ;
Burger, R ;
Warmuth-Metz, M ;
Hofmann, E ;
Solymosi, L .
LANCET, 1999, 354 (9190) :1594-1597
[6]
Benichou H, 1991, Ann Vasc Surg, V5, P21, DOI 10.1007/BF02021772
[7]
Benichou H, 1996, J ENDOVASC SURG, V3, P217, DOI 10.1583/1074-6218(1996)003<0217:CAASWP>2.0.CO
[8]
2
[9]
BERGERON P, 1991, J CARDIOVASC SURG, V32, P713
[10]
Brown MM, 2001, LANCET, V357, P1729