Objective morphological assessment of macular hole surgery by scanning laser tomography

被引:19
作者
Hudson, C
Charles, SJ
Flanagan, JG
Brahma, AK
Turner, GS
McLeod, D
机构
[1] UNIV MANCHESTER,MANCHESTER ROYAL EYE HOSP,DEPT OPHTHALMOL,MANCHESTER M13 9WH,LANCS,ENGLAND
[2] UNIV TORONTO,TORONTO WESTERN HOSP,DEPT OPHTHALMOL,TORONTO,ON M5T 2S8,CANADA
关键词
D O I
10.1136/bjo.81.2.107
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim--To assess the morphological change in retinal topography using a scanning laser tomographer following macular hole surgery. To compare the results of scanning laser tomography with clinical evaluation and visual function assessment. Methods--The sample for this pilot study comprised four eyes exhibiting different stages of macular hole formation preoperatively. Subjects were assessed preoperatively and at 1 and 3 months postoperatively. Each assessment included visual acuity, letter contrast sensitivity, clinical examination (including automated static perimetry), and scanning laser tomography. The Heidelberg retina tomograph (HRT) was used to acquire digitised scanning laser tomography images of the macula (10 degrees and 20 degrees fields). Surgery essentially comprised vitrectomy, peeling of the posterior hyaloid face, if still attached, and intraocular gas tamponade. The magnitude and significance of topographic change were determined postoperatively using the HRT topographic difference facility. Results--Topographic difference analysis of the right and left eyes of case 1 showed a significant reduction in the height of the retina postoperatively. Topographic difference analysis of case 2 showed no significant change in topography. Topographic difference analysis of case 3 showed a significant increase in the height of the retina postoperatively. Scanning laser tomography agreed with clinical assessment based upon fundus biomicroscopy in three of the four eyes studied; the postoperative closure of the stage 2 macular hole (as noted by clinical assessment) proved to be too small to reach statistical significance. Scanning laser tomography agreed with the assessment of visual function in two eyes; the agreement between scanning laser tomography and visual function depends, in part, on the stage of development of the macular hole. Conclusion--Scanning laser tomography provides an objective evaluation of the outcome of macular hole surgery. Studies employing larger sample sizes are required to fully determine the clinical worth of the technique.
引用
收藏
页码:107 / 116
页数:10
相关论文
共 41 条
  • [1] BAILEY IL, 1991, INVEST OPHTH VIS SCI, V32, P422
  • [2] CONFOCAL LASER TOMOGRAPHIC ANALYSIS OF THE RETINA IN EYES WITH MACULAR HOLE FORMATION AND OTHER FOCAL MACULAR DISEASES
    BARTSCH, DU
    INTAGLIETTA, M
    BILLE, JF
    DREHER, AW
    GHARIB, M
    FREEMAN, WR
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (03) : 277 - 287
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] BURK ROW, 1990, SCANNING LASER OPHTH, P161
  • [5] CHRISTMAS NJ, 1995, OPHTHALMOLOGY, V102, P263
  • [6] CIOFFI GA, 1993, OPHTHALMOLOGY, V100, P57
  • [7] REPRODUCIBILITY OF TOPOGRAPHIC MEASUREMENTS OF THE NORMAL AND GLAUCOMATOUS OPTIC-NERVE HEAD WITH THE LASER TOMOGRAPHIC SCANNER
    DREHER, AW
    TSO, PC
    WEINREB, RN
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 111 (02) : 221 - 229
  • [8] ELLIOTT DB, 1993, INVEST OPHTH VIS SCI, V34, P108
  • [9] CLINICOPATHOLOGICAL STUDY OF BILATERAL MACULAR HOLES TREATED WITH PARS-PLANA VITRECTOMY AND GAS TAMPONADE
    FUNATA, M
    WENDEL, RT
    DELACRUZ, Z
    GREEN, WR
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1992, 12 (04): : 289 - 298
  • [10] IDIOPATHIC SENILE MACULAR HOLE - ITS EARLY STAGES AND PATHOGENESIS
    GASS, JDM
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (05) : 629 - 639