Determination of lead in environmental waters with dispersive liquid-liquid microextraction prior to atomic fluorescence spectrometry
被引:137
作者:
Zhou, Qingxiang
论文数: 0引用数: 0
h-index: 0
机构:
Henan Normal Univ, Sch Chem & Environm Sci, Henan Key Lab Environm Pollut Control,Minist Educ, Key Lab Yellow River & Huaihe River Water Environ, Xinxiang 453007, Henan, Peoples R China
China Univ Petr, State Lab Petr Resource & Prospecting, Coll Geosci, Beijing 102249, Peoples R ChinaHenan Normal Univ, Sch Chem & Environm Sci, Henan Key Lab Environm Pollut Control,Minist Educ, Key Lab Yellow River & Huaihe River Water Environ, Xinxiang 453007, Henan, Peoples R China
Zhou, Qingxiang
[1
,2
]
Zhao, Na
论文数: 0引用数: 0
h-index: 0
机构:
China Univ Petr, State Lab Petr Resource & Prospecting, Coll Geosci, Beijing 102249, Peoples R ChinaHenan Normal Univ, Sch Chem & Environm Sci, Henan Key Lab Environm Pollut Control,Minist Educ, Key Lab Yellow River & Huaihe River Water Environ, Xinxiang 453007, Henan, Peoples R China
Zhao, Na
[2
]
Xie, Guohong
论文数: 0引用数: 0
h-index: 0
机构:
Henan Inst Sci & Technol, Coll Resources & Environm, Xinxiang 453003, Peoples R ChinaHenan Normal Univ, Sch Chem & Environm Sci, Henan Key Lab Environm Pollut Control,Minist Educ, Key Lab Yellow River & Huaihe River Water Environ, Xinxiang 453007, Henan, Peoples R China
Xie, Guohong
[3
]
机构:
[1] Henan Normal Univ, Sch Chem & Environm Sci, Henan Key Lab Environm Pollut Control,Minist Educ, Key Lab Yellow River & Huaihe River Water Environ, Xinxiang 453007, Henan, Peoples R China
[2] China Univ Petr, State Lab Petr Resource & Prospecting, Coll Geosci, Beijing 102249, Peoples R China
[3] Henan Inst Sci & Technol, Coll Resources & Environm, Xinxiang 453003, Peoples R China
This paper established a new, rapid and sensitive method for the determination of lead in water samples preconcentrated by dispersive liquid-liquid microextraction (DLLME) prior to atomic fluorescence spectrometry. Dithizone was used as the chelating agent. In the DLLME procedure, lead formed lead-dithizone complex and migrated into the carbon tetrachloride micro-droplets. Important factors that would affect the extraction efficiency had been investigated including the kind and volume of extraction solvent and dispersive solvent, sample pH, the amount of chelating agent, extraction time and centrifugation time. The results showed that the coexisting ions containing in water samples had no obvious negative effect on the determination of lead. The experimental results indicated that the proposed method had a good linear range of 0.01-100 ng mL(-1) (r(2) = 0.9990). The precision was 2.12% (RSD, n = 7) and the detection limit was 0.95 ng L-1. Proposed method was validated with four real environmental samples and the results indicated that the proposed method was excellent for the future use and satisfied spiked recoveries were in the range of 92.9-97.4%. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 42 条
[1]
[Anonymous], 1996, Guidelines for drinking water quality, health criteria and other supporting information, P973