Modified Hadamard transform microchip electrophoresis

被引:12
作者
Guchardi, R [1 ]
Schwarz, MA [1 ]
机构
[1] Univ Basel, Dept Chem, CH-4056 Basel, Switzerland
关键词
dopamine; Hadamard transform electrophoresis; microchip; miniaturization; multiplexing injection; simplified amperometric detection;
D O I
10.1002/elps.200410383
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sensitivity is a crucial point in the development applications for medicine or environmental samples in which the analytes are present in the nanomolar range. Besides further technical development of detection systems, the multiplex sample injection technique can be applied for enhancing the signal-to-noise ratio. Hadamard transform is easily applied to microchip electrophoresis due to the fact that sample injection is generally achieved through cross, double-tee, or tee injector structures. This paper reports the first demonstration of a modified Hadamard transform electrophoresis on a microchip by using an amperometric detector. Contrary to the previous Hadamard applications, the resolution (number of points per unit of time) of electropherograms obtained is independent of the number of injections.
引用
收藏
页码:3151 / 3159
页数:9
相关论文
共 42 条
[1]  
Bellamy MK, 1997, MIKROCHIM ACTA, P759
[2]   SATURATION IN HADAMARD NMR-SPECTROSCOPY AND ITS DESCRIPTION BY A CORRELATION EXPANSION [J].
BLUMICH, B ;
ZIESSOW, D .
JOURNAL OF MAGNETIC RESONANCE, 1982, 46 (03) :385-405
[3]   Hadamard transform time of flight mass spectrometry [J].
Brock, A ;
Rodriguez, N ;
Zare, RN .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3735-3741
[4]   Characterization of a Hadamard transform time-of-flight mass spectrometer [J].
Brock, A ;
Rodriguez, N ;
Zare, RN .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03) :1306-1318
[5]  
Bruin GJM, 2000, ELECTROPHORESIS, V21, P3931, DOI 10.1002/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO
[6]  
2-M
[7]   Shah convolution Fourier transform detection [J].
Crabtree, HJ ;
Kopp, MU ;
Manz, A .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2130-2138
[8]   Lowering the UV absorbance detection limit in capillary zone electrophoresis using a single linear photodiode array detector [J].
Culbertson, CT ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2629-2638
[9]   Hadamard transform time-of-flight mass spectrometry:: A high-speed detector for capillary-format separations [J].
Fernández, FM ;
Vadillo, JM ;
Kimmel, JR ;
Wetterhall, M ;
Markides, K ;
Rodriguez, N ;
Zare, RN .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1611-1617
[10]   Ultrasensitive cross correlation electrophoresis on microchip devices [J].
Fister, JC ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4460-4464