Lessons learned from 500 cases of lymphatic mapping for breast cancer

被引:300
作者
Hill, ADK
Tran, KN
Akhurst, T
Yeung, H
Yeh, SDJ
Rosen, PP
Borgen, PI
Cody, HS
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Surg, Breast Serv, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Nucl Med, New York, NY 10021 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Pathol, New York, NY 10021 USA
关键词
D O I
10.1097/00000658-199904000-00012
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective To evaluate the factors affecting the identification and accuracy of the sentinel node in breast cancer in a single institutional experience. Summary Background Data Few of the many published feasibility studies of lymphatic mapping for breast cancer have adequate numbers to assess in detail the factors affecting failed and falsely negative mapping procedures. Methods Five hundred consecutive sentinel lymph node biopsies were performed using isosulfan blue dye and technetium-labeled sulfur colloid. A planned conventional axillary dissection was performed in 104 cases. Results Sentinel nodes were identified in 458 of 492 (92%) evaluable cases. The mean number of sentinel nodes removed was 2.1. The sentinel node was successfully identified by blue dye in 80% (393/492), by isotope in 85% (419/492), and by the combination of blue dye and isotope in 93% (458/492) of patients. Success in locating the sentinel node was unrelated to tumor size, type, location, or multicentricity; the presence of lymphovascular invasion; histologic or nuclear grade; or a previous surgical biopsy. The false-negative rate of 10.6% (5/47)was calculated using only those 104 cases where a conventional axillary dissection was planned before surgery. Conclusions Sentinel node biopsy in patients with early breast cancer is a safe and effective alternative tb routine axillary dissection for patients with negative nodes. Because of a small but definite rate of false-negative results, this procedure is mast valuable in patients with a low risk of axillary nodal metastases. Both blue dye and radioisotope should be used to maximize the yield and accuracy of successful localizations.
引用
收藏
页码:528 / 535
页数:8
相关论文
共 15 条
[1]   Lymphatic mapping and sentinel node biopsy in the patient with breast cancer [J].
Albertini, JJ ;
Lyman, GH ;
Cox, C ;
Yeatman, T ;
Balducci, L ;
Ku, NN ;
Shivers, S ;
Berman, C ;
Wells, K ;
Rapaport, D ;
Shons, A ;
Horton, J ;
Greenberg, H ;
Nicosia, S ;
Clark, R ;
Cantor, A ;
Reintgen, DS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (22) :1818-1822
[2]   Intradermal blue dye to identify sentinel lymphnode in breast cancer [J].
Borgstein, PJ ;
Meijer, S ;
Pijpers, R .
LANCET, 1997, 349 (9066) :1668-1669
[3]   Guidelines for sentinel node biopsy and lymphatic mapping of patients with breast cancer [J].
Cox, CE ;
Pendas, S ;
Cox, JM ;
Joseph, E ;
Shons, AR ;
Yeatman, T ;
Ku, NN ;
Lyman, GH ;
Berman, C ;
Haddad, F ;
Reintgen, DS .
ANNALS OF SURGERY, 1998, 227 (05) :645-653
[4]  
Giuliano AE, 1996, J AM COLL SURGEONS, V183, P185
[5]   Sentinel lymphadenectomy in breast cancer [J].
Giuliano, AE ;
Jones, RC ;
Brennan, M ;
Statman, R .
JOURNAL OF CLINICAL ONCOLOGY, 1997, 15 (06) :2345-2350
[6]   LYMPHATIC MAPPING AND SENTINEL LYMPHADENECTOMY FOR BREAST-CANCER [J].
GIULIANO, AE ;
KIRGAN, DM ;
GUENTHER, JM ;
MORTON, DL .
ANNALS OF SURGERY, 1994, 220 (03) :391-401
[7]  
Guenther JM, 1997, CANCER J SCI AM, V3, P336
[8]  
KRAG DN, 1998, BREAST J, V4, P67
[9]   Four large studies aim to resolve sentinel node debate [J].
McNeil, C .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1998, 90 (10) :729-729
[10]  
Meijer S, 1996, Ned Tijdschr Geneeskd, V140, P2239