Multi-residue method for non-steroidal anti-inflammatory drugs in plasma using high-performance liquid chromatography photodiode-array detection -: Method description and comprehensive in-house validation

被引:51
作者
Gowik, P
Jülicher, B
Uhlig, S
机构
[1] Fed Inst Hlth Protect Consumers & Vet Med, EU Reference Lab Residues Vet Drugs, D-12277 Berlin, Germany
[2] Free Univ Berlin, Inst Stat & Econometr, D-14195 Berlin, Germany
来源
JOURNAL OF CHROMATOGRAPHY B | 1998年 / 716卷 / 1-2期
关键词
non-steroidal anti-inflammatory drugs;
D O I
10.1016/S0378-4347(98)00343-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A multi-residue high-performance liquid chromatography (HPLC) method with photodiode-array detection is presented for the determination of 12 non-steroidal anti-inflammatory drugs (NSAIDs) in plasma. This method has been validated under the consideration of actual alpha- and beta-errors according to an in-house validation concept based on a fractional factorial experiment. A wide range of matrices and other influencing factors have been included in the validation experiment. In order to assess the method's performance the power curve, which demonstrates the detection power of the analytical method, was computed and CCalpha and CCbeta values were calculated. (C) 1998 Elsevier Science BN. All rights reserved.
引用
收藏
页码:221 / 232
页数:12
相关论文
共 12 条
[1]  
CARTULA C, 1992, J CHROMATOGR, V581, P101
[2]   SPECIMEN HANDLING IN AN HPLC DETERMINATION OF PHENYLBUTAZONE AND ITS MAJOR METABOLITES IN PLASMA, AVOIDING DEGRADATION OF THE COMPOUNDS [J].
FRANSSEN, MJAM ;
TAN, Y ;
FREIJ, I ;
VANGINNEKEN, CAM ;
GRIBNAU, FWJ .
PHARMACEUTISCH WEEKBLAD-SCIENTIFIC EDITION, 1986, 8 (04) :229-233
[3]  
GILMAN AG, 1992, GOODMAN GILMANS PHAR, V1, P638
[4]  
GOWIK P, UNPUB
[5]   SIMULTANEOUS DETERMINATION OF FLUNIXIN, PHENYLBUTAZONE, OXYPHENBUTAZONE AND GAMMA-HYDROXYPHENYLBUTAZONE IN EQUINE PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - WITH APPLICATION TO PHARMACOKINETICS [J].
HARDEE, GE ;
LAI, JW ;
MOORE, JN .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1982, 5 (10) :1991-2003
[6]  
*HWEL, HP CHEMST UND CHEMST
[7]   Assessment of detection methods in trace analysis by means of a statistically based in-house validation concept [J].
Jülicher, B ;
Gowik, P ;
Uhlig, S .
ANALYST, 1998, 123 (02) :173-179
[8]   LONG-TERM EXPOSURE TO THE ANTIINFLAMMATORY AGENT PHENYLBUTAZONE INDUCES KIDNEY TUMORS IN RATS AND LIVER-TUMORS IN MICE [J].
KARI, F ;
BUCHER, J ;
HASEMAN, J ;
EUSTIS, S ;
HUFF, J .
JAPANESE JOURNAL OF CANCER RESEARCH, 1995, 86 (03) :252-263
[9]  
PAPADOYANNIS IN, 1992, J LIQ CHROMATOGR, V15, P1923
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR ANTIINFLAMMATORY AGENTS DICLOFENAC AND FLURBIPROFEN IN OCULAR FLUIDS [J].
RIEGEL, M ;
ELLIS, PP .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 654 (01) :140-145