Amperometric amplification of antigen-antibody association at monolayer interfaces: Design of immunosensor electrodes

被引:52
作者
Katz, E [1 ]
Willner, I [1 ]
机构
[1] HEBREW UNIV JERUSALEM, INST CHEM, IL-91904 JERUSALEM, ISRAEL
关键词
immunosensors; dinitrophenyl antibody; antigen monolayer electrode; amperometric amplification;
D O I
10.1016/S0022-0728(96)04855-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mixed-monolayer of an antigen and electrocatalyst assembled onto Au surfaces acts as an immunosensor electrode for the amplified amperometric detection of the complementary antibody (Ab). In the presence of a substrate for the electrocatalyst, the mixed monolayer electrode yields an electrocatalytic current which is blocked by association of the Ab to the monolayer. A mixed monolayer of N epsilon-2,4-dinitrophenyl lysine and microperoxidase-11 assembled on an Au electrode is applied to the amperometric detection of the dinitrophenyl antibody (DNP-Ab) in the presence of persulfate, S2O82-, acting as substrate for the microperoxidase electrocatalyst. Similarly, a mixed-monolayer of N epsilon-2,4-dinitrophenyl lysine and pyrroloquinoline quinone (PQQ) assembled on an Au surface acts as an immunosensing electrode for the DNP-Ab in the presence of 1,4-dihydronicotinamide adenine dinucleotide (NADH) and Ca2+ ions. The electrocatalytic oxidation of NADH in the presence of Ca2+ ions by the PQQ electrocatalyst, and the inhibition of the electrocatalyzed process upon association of the DNP-Ab to the electrode, are used in the analytical sensing of the DNP-Ab. The electrode is sensitive for determination of the DNP-Ab in the concentration range 0.2-20 mu g ml(-1).
引用
收藏
页码:67 / 72
页数:6
相关论文
共 55 条
  • [1] OXYGEN ELECTRODE-BASED ENZYME-IMMUNOASSAY FOR THE AMPEROMETRIC DETERMINATION OF HEPATITIS-B SURFACE-ANTIGEN
    BOITIEUX, JL
    THOMAS, D
    DESMET, G
    [J]. ANALYTICA CHIMICA ACTA, 1984, 163 (SEP) : 309 - 313
  • [2] BRESLER HS, 1992, ACS SYM SER, V511, P89
  • [3] Cass A. E. G., 1990, BIOSENSORS PRACTICAL
  • [4] THE DEVELOPMENT OF REDOX-MODIFIED ELECTRODES AS CHARGE-ACCUMULATING DEVICES FOR USE IN HIGHER SENSITIVITY DETECTION SYSTEMS
    CHAMBERS, JA
    WALTON, NJ
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 250 (02): : 417 - 425
  • [5] COHEN Y, IN PRESS J ELECTROAN
  • [6] USE OF SCANNING PROBE MICROSCOPY AND SURFACE-PLASMON RESONANCE AS ANALYTICAL TOOLS IN THE STUDY OF ANTIBODY-COATED MICROTITER WELLS
    DAVIES, J
    ROBERTS, CJ
    DAWKES, AC
    SEFTON, J
    EDWARDS, JC
    GLASBEY, TO
    HAYMES, AG
    DAVIES, MC
    JACKSON, DE
    LOMAS, M
    SHAKESHEFF, KM
    TENDLER, SJB
    WILKINS, MJ
    WILLIAMS, PM
    [J]. LANGMUIR, 1994, 10 (08) : 2654 - 2661
  • [7] DEALWIS WU, 1985, ANAL CHEM, V57, P2754
  • [8] EUROPIUM CHELATE LABELS IN TIME-RESOLVED FLUORESCENCE IMMUNOASSAYS AND DNA HYBRIDIZATION ASSAYS
    DIAMANDIS, EP
    CHRISTOPOULOS, TK
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (22) : A1149 - +
  • [9] HOMOGENEOUS FERROCENE-MEDIATED AMPEROMETRIC IMMUNOASSAY
    DIGLERIA, K
    HILL, HAO
    MCNEIL, CJ
    GREEN, MJ
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (06) : 1203 - 1205
  • [10] HOMOGENEOUS AMPEROMETRIC LIGAND-BINDING ASSAY AMPLIFIED BY A PROTEOLYTIC-ENZYME CASCADE
    DIGLERIA, K
    HILL, HAO
    CHAMBERS, JA
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 267 (1-2): : 83 - 91