Monte Carlo simulations of a scintillation camera using GATE: validation and application modelling

被引:94
作者
Staelens, S
Strul, D
Santin, G
Vandenberghe, S
Koole, M
D'Asseler, Y
Lemahieu, I
van de Walle, R
机构
[1] Univ Ghent, ELIS Dept, B-9000 Ghent, Belgium
[2] Univ Lausanne, IPHE, CH-1015 Lausanne, Switzerland
[3] European Space Agcy, Estec, NL-2200 AG Noordwijk, Netherlands
关键词
Cameras - Computer simulation - Fluorescence - Isotopes - Mathematical models - Monte Carlo methods - Photoelectricity - Scintillation;
D O I
10.1088/0031-9155/48/18/305
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Geant4 application for tomographic emission (GATE) is a recently developed simulation platform based on Geant4, specifically designed for PET and SPECT studies. In this paper we present validation results of GATE based on the comparison of simulations against experimental data, acquired with a standard SPECT camera. The most important components of the scintillation camera were modelled. The photoelectric effect, Compton and Rayleigh scatter are included in the gamma transport process. Special attention was paid to the processes involved in the collimator: scatter, penetration and lead fluorescence. A LEHR and a MEGP collimator were modelled as closely as possible to their shape and dimensions. In the validation study, we compared the simulated and measured energy spectra of different isotopes: Tc-99m, Na-22, Co-57 and Ga-67. The sensitivity was evaluated by using sources at varying distances from the detector surface. Scatter component analysis was performed in different energy windows at different distances from the detector and for different attenuation geometries. Spatial resolution was evaluated using a Tc-99m source at various distances. Overall results showed very good agreement between the acquisitions and the simulations. The clinical usefulness of GATE depends on its ability to use voxelized datasets. Therefore, a clinical extension was written so that digital patient data can be read in by the simulator as a source distribution or as an attenuating geometry. Following this validation we modelled two additional camera designs: the Beacon transmission device for attenuation correction and the Solstice scanner prototype with a rotating collimator. For the first setup a scatter analysis was performed and for the latter design, the simulated sensitivity results were compared against theoretical predictions. Both case studies demonstrated the flexibility and accuracy of GATE and exemplified its potential benefits in protocol optimization and in system design.
引用
收藏
页码:3021 / 3042
页数:22
相关论文
共 23 条
[1]  
AGOSTINELLI S, 2002, SLACPUB9350
[2]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[3]   GAMMA-RAY DETECTION EFFICIENCY + IMAGE RESOLUTION IN SODIUM IODIDE [J].
ANGER, HO ;
DAVIS, DH .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1964, 35 (06) :693-&
[4]  
BRIESMEISTER JF, 1988, LA12625M
[5]   ROOT - An object oriented data analysis framework [J].
Brun, R ;
Rademakers, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 389 (1-2) :81-86
[6]  
Buvat I, 2002, Q J NUCL MED, V46, P48
[7]   Combination of MCNP and SimSET for Monte Carlo simulation of SPECT with medium- and high-energy photons [J].
Du, Y ;
Frey, EC ;
Wang, WT ;
Tocharoenchai, C ;
Baird, WH ;
Tsui, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) :668-674
[8]  
GAGNON D, 2001, IEEE NUCL SCI MED IM, V2, P1156
[9]  
GRIESMER J, 2001, P IEEE MED IM SAN DI, V2, P1050
[10]  
HARRISON RL, 1993, J NUCL MED, V34, pP60