Speciation of Al in human serum by convective-interaction media fast-monolithic chromatography with inductively coupled plasma mass spectrometric detection

被引:33
作者
Murko, Simona [1 ]
Milacic, Radmila [1 ]
Scancar, Janez [1 ]
机构
[1] Jozef Stefan Inst, Dept Environm Sci, Ljubljana 1000, Slovenia
关键词
high molecular mass Al species; human serum; size exclusion chromatography; convective-interaction media diethylamine fast-monolithic chromatography; UV detection; ICP-MS;
D O I
10.1016/j.jinorgbio.2007.06.013
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A new analytical procedure using anion-exchange separation support based on convective-interaction media (CIM) was developed for the speciation of Al in human serum. The separation of proteins was performed on a weak anion-exchange CIM diethylamine (DEAE) fast-monolithic disk. To prevent co-elution of low molecular mass (LMM) Al species with high molecular mass (HMM) Al compounds on CIM disk serum proteins were first separated from LMM-Al species by the use of size exclusion chromatography (SEC). For this purpose 1 mL of serum was injected onto SEC (Superdex 75 HR 10/30) column. Isocratic elution using 0.05 M TRIS-HCl + 0.03 M NaHCO3 was applied and separation of proteins was followed by UV detection at 278 nm. It was experimentally proven that proteins were eluted in 5.5 mL peak that was collected into a polyethylene cup. A 0.1 mL of the sample aliquot was then injected onto the CIM DEAE disk. The separation of serum proteins was obtained in 10 min by applying linear gradient elution from 100% buffer A (0.05 M TRIS-HCl + 0.03 M NaHCO3) to 100% buffer B (A + 1 M NH4Cl) and followed by UV detection at 278 nm. Separated Al species were detected on-line by inductively coupled plasma mass spectrometry (ICP-MS). Well-resolved protein peaks were obtained. It was experimentally proven that 90 +/- 3% of Al in spiked serum of renal patient was eluted under the transferrin peak. The proposed speciation procedure removes LMM-Al species and enables reliable determination of the concentration and composition of Al bound to proteins by CIM DEAE-ICP-MS when the concentration of Al in serum is higher than 5 ng mL(-1). In comparison to chromatographic columns CIM disks enable faster separation and simpler manipulation during cleaning procedure and coupling to ICP-MS. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:1234 / 1241
页数:8
相关论文
共 38 条
[1]
DIALYSIS ENCEPHALOPATHY SYNDROME - POSSIBLE ALUMINUM INTOXICATION [J].
ALFREY, AC ;
LEGENDRE, GR ;
KAEHNY, WD .
NEW ENGLAND JOURNAL OF MEDICINE, 1976, 294 (04) :184-188
[2]
ALUMINUM AND THE PATHOGENESIS OF DIALYSIS ENCEPHALOPATHY [J].
ARIEFF, AI .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1985, 6 (05) :317-321
[3]
Investigation of low molecular weight Al complexes in human serum by fast protein liquid chromatography (FPLC)-ETAAS and electrospray (ES)-MS-MS techniques [J].
Bantan, T ;
Milacic, R ;
Mitrovic, B ;
Pihlar, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (11) :1743-1748
[4]
Quantitative determination of trace amounts of Al-citrate by anion-exchange FPLC-ETAAS [J].
Bantan, T ;
Milacic, R ;
Pihlar, B .
TALANTA, 1998, 47 (04) :929-941
[5]
Barut M., 1999, AM BIOTECHNOL LAB, V17, P48
[6]
BERTHOLF RL, 1986, TRACE ELEM MED, V3, P157
[7]
BLANCOGONZALEZ E, 1989, J ANAL ATOM SPECTROM, V4, P175
[8]
Very fast analysis of impurities in immunoglobulin concentrates using conjoint liquid chromatography on short monolithic disks [J].
Branovic, K ;
Lattner, G ;
Barut, M ;
Strancar, A ;
Josic, D ;
Buchacher, A .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 271 (1-2) :47-58
[9]
Cabezuelo ABS, 1998, ANALYST, V123, P865
[10]
Cabezuelo ABS, 1997, ANALYST, V122, P573, DOI 10.1039/a608258k