Electronic nose prediction of a clinical pneumonia score: Biosensors and microbes

被引:75
作者
Hanson, CW
Thaler, ER
机构
[1] Hosp Univ Penn, Dept Anesthesiol, Philadelphia, PA 19104 USA
[2] Hosp Univ Penn, Dept Otorhinolaryngol, Philadelphia, PA 19104 USA
关键词
D O I
10.1097/00000542-200501000-00013
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The authors performed a prospective study to determine whether breath test analysis using an electronic nose correlates with a clinical pneumonia score. Methods: Exhaled gas was sampled from the expiratory limb of the ventilator in mechanically ventilated surgical intensive care patients and assayed with the electronic nose. Components of a clinical pneumonia score were recorded concurrently. Results: The score predicted by the electronic nose showed good correlation with the actual pneumonia score (r(2) = 0.81). Bland Altman analysis showed a mean bias of 0.0 (limits +/- 2.6). Conclusions: The electronic nose is a new biosensor technology that correlates with a clinical pneumonia score.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 42 条
[1]   MICROBIOLOGICAL LUNG SURVEILLANCE IN MECHANICALLY VENTILATED PATIENTS, USING NON-DIRECTED BRONCHIAL LAVAGE AND QUANTITATIVE CULTURE [J].
ACOURT, CHD ;
GARRARD, CS ;
CROOK, D ;
BOWLER, I ;
CONLON, C ;
PETO, T ;
ANDERSON, E .
QUARTERLY JOURNAL OF MEDICINE, 1993, 86 (10) :635-648
[2]   Antimicrobial resistance in isolates from inpatients and outpatients in the united states: Increasing importance of the intensive care unit [J].
Archibald, L ;
Phillips, L ;
Monnet, D ;
McGowan, JE ;
Tenover, F ;
Gaynes, R .
CLINICAL INFECTIOUS DISEASES, 1997, 24 (02) :211-215
[3]   BREATH ANALYSIS BY API MS - HUMAN EXPOSURE TO VOLATILE ORGANIC-SOLVENTS [J].
BENOIT, FM ;
DAVIDSON, WR ;
LOVETT, AM ;
NACSON, S ;
NGO, A .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1985, 55 (02) :113-120
[4]   THE PARTIAL LEAST-SQUARES FIX POINT METHOD OF ESTIMATING INTERDEPENDENT SYSTEMS WITH LATENT-VARIABLES [J].
BOARDMAN, AE ;
HUI, BS ;
WOLD, H .
COMMUNICATIONS IN STATISTICS PART A-THEORY AND METHODS, 1981, 10 (07) :613-639
[5]   Does an analysis of exhaled air indicate the metabolic state of critically ill patients? [J].
Borner, U ;
Klimek, M .
INTENSIVE CARE MEDICINE, 1998, 24 (05) :403-404
[6]   MEASUREMENT OF THE BIOTRANSFER AND TIME CONSTANT OF RADON FROM INGESTED WATER BY HUMAN BREATH ANALYSIS [J].
BROWN, WL ;
HESS, CT .
HEALTH PHYSICS, 1992, 62 (02) :162-170
[7]   D-GALACTOSE-C-14 BREATH TEST FOR EVALUATION OF LIVER-FUNCTION IN PATIENTS WITH CHRONIC LIVER-DISEASE [J].
CASPARY, WF ;
SCHAFFER, J .
DIGESTION, 1978, 17 (05) :410-418
[8]   Screening for bacterial vaginosis: a novel application of artificial nose technology [J].
Chandiok, S ;
Crawley, BA ;
Oppenheim, BA ;
Chadwick, PR ;
Higgins, S ;
Persaud, KC .
JOURNAL OF CLINICAL PATHOLOGY, 1997, 50 (09) :790-791
[9]   The lipid membrane hypothesis of schizophrenia: Implications for possible clinical breath tests [J].
Dodd, GH .
PROSTAGLANDINS LEUKOTRIENES AND ESSENTIAL FATTY ACIDS, 1996, 55 (1-2) :95-99
[10]   OCCUPATIONAL EXPOSURE MONITORING USING BREATH ANALYSIS [J].
DROZ, PO ;
GUILLEMIN, MP .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1986, 28 (08) :593-602