A validated SPME-GC-MS method for simultaneous quantification of club drugs in human urine

被引:72
作者
Brown, Stacy D. [1 ]
Rhodes, Daniel J. [1 ]
Pritchard, Boyd J. [1 ]
机构
[1] Citadel, Dept Chem, Charleston, SC 29409 USA
关键词
club drugs; SPME; GC-MS; validation;
D O I
10.1016/j.forsciint.2006.10.015
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
A solid-phase microextraction-gas chromatographic-mass spectrometric (SPME-GC-MS) method has been developed and validated for measuring four club drugs in human urine. These drugs include gamma-hydroxybutyrate (GHB), ketamine (KET), methamphetamine (MAMP), and methylenedioxyrnethamphetamine (MDMA). These drugs are referred to as 'club drugs' because of their prevalence at parties and raves. Deuterium labeled internal standards for each of the four drugs was included in the assay to aid in quantitation. The drugs were spiked into human urine and derivatized using pyridine and hexylchloroformate to make them suitable for GC-MS analysis. The SPME conditions of extraction time/temperature and desorption time/temperature were optimized to yield the highest peak area for each of the four drugs. The final SPME parameters included a 90 degrees C extraction for 20 min with a I min desorption in the GC injector at 225 degrees C using a splitless injection. All SPME work was done using a 100 mu m PDMS fiber by Supelco. The ratio of pyridine to hexylchloroformate for derivatization was also optimized. The GC separation was carried out on a VF-5ht column by Varian (30 m, 0.25 mm i.d., 0.10 mu m film thickness) using a temperature program of 150-270 degrees C at 10 degrees C/min. The instrument used was a ThermoFinnigan Trace GC-Polaris Q interfaced with a LEAP CombiPal autosampler. The data was collected by using extracted ion chromatograms of marker m/z values for each drug from the total ion chromatograms (TIC) (full scan mode). Calibration curves with R-2 > 0.99 were generated each day using the peak area ratios (peak area drug/peak area internal standard) versus concentration. The validated method resulted in intra-day and inter-day precision (% R. S.D.) of less than 15% and a % error of less than 15% for four concentrations in the range of 0.05-20 mu g/mL (MAMP) and 0.10-20 mu g/mL (GHB, KET, and MDMA). This method has the advantage of an easy sample preparation with acceptable accuracy and precision for the simultaneous quantification of these four drugs of abuse and shows no interference from the urine matrix. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:142 / 150
页数:9
相关论文
共 29 条
[1]  
Blair S, 2001, J FORENSIC SCI, V46, P688
[2]   GAS-CHROMATOGRAPHIC ASSAY FOR KETAMINE IN HUMAN PLASMA [J].
CHANG, T ;
GLAZKO, AJ .
ANESTHESIOLOGY, 1972, 36 (04) :401-&
[3]   Determination of γ-hydroxybutyrate (GHB) in biological specimens by cas chromatography -: Mass spectrometry [J].
Couper, FJ ;
Logan, BK .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (01) :1-7
[4]   GC-MS determination of gamma-hydroxybutyric acid (GHB) in blood [J].
Elian, AA .
FORENSIC SCIENCE INTERNATIONAL, 2001, 122 (01) :43-47
[5]   A novel method for GHB detection in urine and its application in drug-facilitated sexual assaults [J].
Elian, AA .
FORENSIC SCIENCE INTERNATIONAL, 2000, 109 (03) :183-187
[6]   Prevalence of drugs used in cases of alleged sexual assault [J].
ElSohly, MA ;
Salamone, SJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1999, 23 (03) :141-146
[7]  
FEERRARA SD, 1993, J PHARM BIOMED ANAL, V11, P483
[8]   One step and highly sensitive headspace solid-phase microextraction sample preparation approach for the analysis of methamphetamine and amphetamine in human urine [J].
Huang, MK ;
Liu, CR ;
Huang, SD .
ANALYST, 2002, 127 (09) :1203-1206
[9]   Rapid analysis of amphetamine, methamphetamine, MDA, and MDMA in urine using solid-phase microextraction, direct on-fiber derivatization, and analysis by GC-MS [J].
Jurado, C ;
Giménez, MP ;
Soriano, T ;
Menéndez, M ;
Repetto, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (01) :11-16
[10]  
Kintz P, 2003, J FORENSIC SCI, V48, P195