Quantification of triiodinated benzene derivatives and X-ray contrast media in water samples by liquid chromatography-electrospray tandem mass spectrometry

被引:80
作者
Putschew, A [1 ]
Schittko, S [1 ]
Jekel, M [1 ]
机构
[1] Tech Univ Berlin, Inst Environm Technol, Dept Water Qual Control, D-10623 Berlin, Germany
关键词
water analysis; liquid chromatography-tandem mass spectrometry; X-ray contrast media; triiodinated benzene derivatives;
D O I
10.1016/S0021-9673(01)01186-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for the analysis of iodinated X-ray contrast media and possible metabolites in environmental water samples is presented. The method consists of a sequential solid-phase extraction followed by high-performance liquid chromatography coupled with tandem mass spectrometry for detection. The recoveries for the analytes in tap water varies between 70 and 100%. For matrix poor samples the detection limit is in the lower ng/l range. In case of native, complex samples the recoveries are lower and the parallel analysis of a spiked sample is necessary to obtain reliable data. With the presented method iodinated X-ray contrast media could be detected and quantified in a sewage treatment plant effluent, in a receiving channel and lake. In the receiving lake the concentrations are still high with values between 0.5 and 4 mug/l. (C) 2001 Elsevier Science B.V All rights reserved.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 10 条
[1]  
DUNN J, 1990, INVEST RADIOL, V23, P89
[2]   Contamination of hospital wastewater with hazardous compounds as defined by 7a WHG [J].
Gartiser, S ;
Brinker, L ;
Erbe, T ;
Kümmerer, K ;
Willmund, R .
ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 1996, 24 (02) :90-97
[3]   Detection and identification of sulphonamide drugs in municipal waste water by liquid chromatography coupled with electrospray ionisation tandem mass spectrometry [J].
Hartig, C ;
Storm, T ;
Jekel, M .
JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) :163-173
[4]   A sensitive method for the determination of iodine containing diagnostic agents in aqueous matrices using LC-electrospray-tandem-MS detection [J].
Hirsch, R ;
Ternes, TA ;
Lindart, A ;
Haberer, K ;
Wilken, RD .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (08) :835-841
[5]   Biodegradation of the iodinated X-ray contrast media diatrizoate and iopromide [J].
Kalsch, W .
SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 225 (1-2) :143-153
[6]  
OBERDISSE E, 1999, PHARM TOXIKOLOGIE, P597
[7]   Application of ion-chromatography for the determination of the organic-group parameters AOCl, AOBr and AOI in water [J].
Oleksy-Frenzel, J ;
Wischnack, S ;
Jekel, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (01) :89-94
[8]  
OLEKSYFRENZEL J, 1995, VOM WASSER, V85, P59
[9]   Occurrence of triiodinated X-ray contrast agents in the aquatic environment [J].
Putschew, A ;
Wischnack, S ;
Jekel, M .
SCIENCE OF THE TOTAL ENVIRONMENT, 2000, 255 (1-3) :129-134
[10]   Occurrence and behavior of X-ray contrast media in sewage facilities and the aquatic environment [J].
Ternes, TA ;
Hirsch, R .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (13) :2741-2748