Rapid and unbiased estimation of the volume of cutaneous malignant melanoma using Cavalieri's principle

被引:14
作者
Bahmer, FA
Hantirah, S
Baum, HP
机构
[1] UNIV HOSP SAARLAND,DEPT DERMATOL,HOMBURG,GERMANY
[2] KING FAISAL HOSP,TABUK,SAUDI ARABIA
关键词
Cavalieri principle; malignant melanoma; morphometry; point counting; stereology; volume;
D O I
10.1097/00000372-199604000-00009
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
The Cavalieri volume estimator has been employed to determine the macroscopic tumor volume of 34 cutaneous malignant melanomas. With this rapid and unbiased method using histological specimens from slabs of known thickness, tumor volumes between 3.9 mm(3) and 841.5 mm(3) were found. The coefficient of error (CE) for tumor volumes ranged between 0.028 and 0.141, with a combined group CE of 0.043. Then was a remarkably good correlation between tumor volume and maximal vertical tumor thickness estimated according to Breslow, with a correlation coefficient of r = 0.86 for all tumors, and of r = 0.82, if the one extremely big tumor is omitted. Both inter- and intraobserver variability was very low, with only similar to 1-2% difference. Thus, the method described allows for the reproducible, rapid, and unbiased estimation of tumor volume independent of the shape of the tumor.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 19 条
[1]  
Bahmer F A, 1990, Z Hautkr, V65, P901
[2]  
BALCH CM, 1992, CUTANEOUS MELANOMA, P165
[4]   RECENT STEREOLOGICAL METHODS FOR CELL BIOLOGY - A BRIEF SURVEY [J].
CRUZORIVE, LM ;
WEIBEL, ER .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (04) :L148-L156
[5]  
FRIEDMAN RJ, 1991, DERMATOL CLIN, V9, P643
[6]  
GEBHART W, 1984, AM J DERMATOPATH, V6, P93
[7]   THICKNESS IS NOT AN ACCURATE GAUGE OF PROGNOSIS OF PRIMARY CUTANEOUS MELANOMA [J].
GREEN, MS ;
ACKERMAN, AB .
AMERICAN JOURNAL OF DERMATOPATHOLOGY, 1993, 15 (05) :461-473
[8]   SOME NEW, SIMPLE AND EFFICIENT STEREOLOGICAL METHODS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS - REVIEW ARTICLE [J].
GUNDERSEN, HJG ;
BENDTSEN, TF ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (05) :379-394
[9]   THE NEW STEREOLOGICAL TOOLS - DISECTOR, FRACTIONATOR, NUCLEATOR AND POINT SAMPLED INTERCEPTS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS [J].
GUNDERSEN, HJG ;
BAGGER, P ;
BENDTSEN, TF ;
EVANS, SM ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (10) :857-881
[10]   STEREOLOGY OF ARBITRARY PARTICLES - A REVIEW OF UNBIASED NUMBER AND SIZE ESTIMATORS AND THE PRESENTATION OF SOME NEW ONES, IN MEMORY OF THOMPSON,WILLIAM,R. [J].
GUNDERSEN, HJG .
JOURNAL OF MICROSCOPY, 1986, 143 :3-45