Critical load bus voltage control using DVR under system frequency variation

被引:27
作者
Jindal, Amit Kumar [2 ]
Ghosh, Arindam [1 ]
Joshi, Avinash [2 ]
机构
[1] Queensland Univ Technol, Sch Engn Syst, Brisbane, Qld 4001, Australia
[2] Indian Inst Technol, Dept Elect Engn, Kanpur 208016, Uttar Pradesh, India
关键词
critical load; DVR; distribution system; nominal frequency; power quality; voltage control; VSI;
D O I
10.1016/j.epsr.2007.02.006
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper discusses the voltage control of a critical load bus using a dynamic voltage restorer (DVR) in a distribution system. The critical load requires a balanced sinusoidal waveform across its terminals preferably at system nominal frequency of 50 Hz. It is assumed that the frequency of the supply voltage can vary and is different from the system nominal frequency. The DVR is operated such that it holds the voltage across the critical load bus terminals constant at system nominal frequency irrespective of the frequency of the source voltage. In case of a frequency mismatch, the total real power requirement of the critical load has to be supplied by the DVR. To compensate for frequency variation, the dc link of the DVR is supplied through an uncontrolled rectifier that provides a path for the real power required by the critical load to flow. A simple frequency estimation technique is discussed which uses a moving average process along with zero-crossing detector. Through detailed analysis and simulation studies using PSCAD/EMTDC it is shown that the voltage is completely controlled across the critical load. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:255 / 263
页数:9
相关论文
共 12 条
[1]  
[Anonymous], 2012, Power quality enhancement using custom power devices
[2]  
[Anonymous], 6100021 IEC
[3]   Frequency estimation of distorted power system signals using extended complex Kalman filters [J].
Dash, PK ;
Pradhan, AK ;
Panda, G .
IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (03) :761-766
[4]  
Dugan R., 2003, Electrical Power Systems Quality, VSecond
[5]   Design of a capacitor-supported dynamic voltage restorer (DVR) for unbalanced and distorted loads [J].
Ghosh, A ;
Jindal, AK ;
Joshi, A .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) :405-413
[6]  
*IEEE STAND, 1995, P11591195 IEEE
[7]   Online estimation of steady state and instantaneous symmetrical components [J].
Iravani, MR ;
Karimi-Ghartemani, M .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (05) :616-622
[8]  
KENNEDY K, 2003, P IEEE POW ENG SOC G, V2, P757
[9]   A NEW MEASUREMENT TECHNIQUE FOR TRACKING VOLTAGE PHASORS, LOCAL SYSTEM FREQUENCY, AND RATE OF CHANGE OF FREQUENCY [J].
PHADKE, AG ;
THORP, JS ;
ADAMIAK, MG .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (05) :1025-1038
[10]   Accurate measurement of power system frequency using a digital signal processing technique [J].
Sidhu, TS .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (01) :75-81