Effects of aging on left atrial reservoir, conduit, and booster pump function: a multi-institution acoustic quantification study

被引:155
作者
Spencer, KT
Mor-Avi, V
Gorcsan, J
DeMaria, AN
Kimball, TR
Monaghan, MJ
Perez, JE
Weinert, L
Bednarz, J
Edelman, K
Kwan, OL
Glascock, B
Hancock, J
Baumann, C
Lang, RM
机构
[1] Univ Chicago, Chicago, IL 60637 USA
[2] Univ Pittsburgh, Pittsburgh, PA 15260 USA
[3] Univ Calif San Diego, La Jolla, CA 92093 USA
[4] Childrens Hosp, Cincinnati, OH 45229 USA
[5] Kings Coll London, London WC2R 2LS, England
[6] Washington Univ, St Louis, MO USA
关键词
aging; atrium; echocardiography;
D O I
10.1136/heart.85.3.272
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To assess the feasibility of measuring left atrial (LA) function with acoustic quantification (AQ) and then assess the effects of age and sex on LA reservoir, conduit, and booster pump function. Patients and setting-165 subjects without cardiovascular disease, 3-79 years old, were enrolled by six tertiary hospital centres. Interventions-Continuous LA AQ area data were acquired and signal averaged to form composite waveforms which were analysed off-line. Main outcome measures-Parameters of LA performance according to age and sex. Results-Signal averaged LA waveforms were sufficiently stable and detailed to allow automated analysis in all cases. An age related increase in LA area was noted. LA reservoir function did not vary with age or sex. All parameters of LA passive and active emptying revealed a significant age dependency. Overall, the passive emptying phase accounted for 66% of total LA emptying ranging from 76% in the youngest to 44% in the oldest decade. LA contraction accounted for 34% of atrial emptying in all subjects combined with the older subjects being more dependent on atrial booster pump function. When adjusted for atrial size, there were no sex related differences in LA function. Conclusions-LA reservoir, conduit, and booster pump function can be assessed with automated analysis of signal averaged LA area waveforms. As LA performance varies with age, establishment of normal values should enhance the evaluation of pathologic states in which LA function is important.
引用
收藏
页码:272 / 277
页数:6
相关论文
共 32 条
[1]   INSTANTANEOUS PRESSURE-VOLUME RELATION OF THE EJECTING CANINE LEFT ATRIUM [J].
ALEXANDER, J ;
SUNAGAWA, K ;
CHANG, N ;
SAGAWA, K .
CIRCULATION RESEARCH, 1987, 61 (02) :209-219
[2]   LEFT ATRIAL FUNCTION AND VENTRICULAR FILLING IN HYPERTENSIVE PATIENTS WITH PAROXYSMAL ATRIAL-FIBRILLATION [J].
BARBIER, P ;
ALIOTO, G ;
GUAZZI, MD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (01) :165-170
[3]  
Bednarz J E, 1995, J Am Soc Echocardiogr, V8, P293, DOI 10.1016/S0894-7317(05)80040-9
[4]   MEASUREMENT OF NORMAL LEFT ATRIAL FUNCTION WITH GATED RADIONUCLIDE ANGIOGRAPHY [J].
BOUGH, EW ;
GANDSMAN, EJ ;
SHULMAN, RS .
AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (03) :473-478
[5]  
CLARKSON PBM, 1995, BRIT HEART J, V74, P664
[6]  
CRESCI S, 1995, J HEART LUNG TRANSPL, V14, P647
[7]   Left atrial mechanical adaptation to long-standing hemodynamic loads based on pressure-volume relations [J].
Dernellis, JM ;
Stefanadis, CI ;
Zacharoulis, AA ;
Toutouzas, PK .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (09) :1138-1143
[8]  
Feinberg M S, 1995, J Am Soc Echocardiogr, V8, P139, DOI 10.1016/S0894-7317(05)80403-1
[9]  
Gorcsan J 3rd, 1993, J Am Soc Echocardiogr, V6, P482
[10]   IN-VIVO ASSESSMENT OF LEFT ATRIAL CONTRACTILE PERFORMANCE IN NORMAL AND PATHOLOGICAL CONDITIONS USING A TIME-VARYING ELASTANCE MODEL [J].
HOIT, BD ;
SHAO, YF ;
GABEL, M ;
WALSH, RA .
CIRCULATION, 1994, 89 (04) :1829-1838