Long-term results of the threaded Mecron cup in primary total hip arthroplasty

被引:21
作者
Clarius, Michael [1 ]
Jung, Alexander W. [1 ]
Streit, Marcus R. [1 ]
Merle, Christian [1 ]
Raiss, Patric [1 ]
Aldinger, Peter R. [1 ]
机构
[1] Stiftung Orthopad Univ Klin Heidelberg, D-69118 Heidelberg, Germany
关键词
10-YEAR FOLLOW-UP; RECTANGULAR TITANIUM STEM; ACETABULAR COMPONENTS; SURFACE-TREATMENT; SURVIVAL ANALYSIS; SCREW CUP; MINIMUM; FAILURE; RING; REPLACEMENT;
D O I
10.1007/s00264-009-0843-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
In the 1970s, high failure rates of cemented acetabular components, especially in young patients, in the middle- and long-term prompted a search for alternatives. The Mecring was one of the most popular first generation uncemented, threaded cups widely used in the 1980s for arthroplasty of the hip. First generation threaded cups commonly had smooth surface treatment and showed unacceptably high failure rates in the midterm. In a consecutive series of 209 patients, 221 threaded uncemented acetabular cups with smooth surface treatment (Mecring) had been implanted in combination with one type of uncemented stem. Patients were followed up clinically and radiographically. The mean time of follow-up was 17 (range 15-20) years. In 91 (41%) hips the acetabular component had been revised or was awaiting revision: two hips for infection and 84 (38%) for aseptic loosening. Five hips were awaiting revision. The survival rate for all revisions including hips awaiting revision was 49% (95% Cl: 41-57%) at 17 years. These results support the view that smooth, threaded acetabular components do not provide satisfactory long-term fixation and should be abandoned. Patients with these components must be closely monitored as the failure rate remains high in the long-term.
引用
收藏
页码:1093 / 1098
页数:6
相关论文
共 33 条
[1]
Survival of the Cementless SpotornoA® Stem in the Second Decade [J].
Aldinger, Peter R. ;
Jung, Alexander W. ;
Breusch, Steffen J. ;
Ewerbeck, Volker ;
Parsch, Dominik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (09) :2297-2304
[2]
Uncemented Grit-Blasted Straight Tapered Titanium Stems in Patients Younger than Fifty-five Years of Age Fifteen to Twenty-Year Results [J].
Aldinger, Peter R. ;
Jung, Alexander W. ;
Pritsch, Maria ;
Breusch, Steffen ;
Thomsen, Marc ;
Ewerbeck, Volker ;
Parsch, Dominik .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06) :1432-1439
[3]
Long-term fate of uncemented, threaded acetabular components with smooth surface treatment: minimum 10-year follow-up of two different designs [J].
Aldinger, PR ;
Thomsen, M ;
Lukoschek, M ;
Mau, H ;
Ewerbeck, V ;
Breusch, SJ .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (07) :469-475
[4]
Pattern of periprosthetic bone remodeling around stable uncemented tapered hip stems: A prospective 84-month follow-up study and a median 156-month cross-sectional study with DXA [J].
Aldinger, PR ;
Sabo, D ;
Pritsch, M ;
Thomsen, M ;
Mau, H ;
Ewerbeck, V ;
Breusch, SJ .
CALCIFIED TISSUE INTERNATIONAL, 2003, 73 (02) :115-121
[5]
FAILURE OF THE MECRING SCREW-RING ACETABULAR COMPONENT IN TOTAL HIP-ARTHROPLASTY - A 3-YEAR TO 7-YEAR FOLLOW-UP-STUDY [J].
BRUIJN, JD ;
SEELEN, JL ;
FEENSTRA, RM ;
HANSEN, BE ;
BERNOSKI, FP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (05) :760-766
[6]
FAILURE OF THE MECRON SCREW-IN RING [J].
CAPELLO, WN ;
COLYER, RA ;
KERNEK, CB ;
CARNAHAN, JV ;
HESS, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (05) :835-836
[7]
Charnley J., 1979, LOW FRICTION ARTHROP
[8]
FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS [J].
DAUBIGNE, RM ;
POSTEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) :451-475
[9]
Survival analysis of cementless grit-blasted titanium total hip arthroplasties [J].
Delaunay, C ;
Kapandji, AI .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (03) :408-413
[10]
Delaunay CP, 1997, CLIN ORTHOP RELAT R, P130