The purpose of this study was to evaluate a percutaneous vascular suture (PVS) device in patients with peripheral arterial occlusive disease (PAOD) for achievement of immediate hemostasis at the vascular access site and early ambulation of fully anticoagulated patients after peripheral interventional procedures. From June 1995 to March 2000, a vascular suture using a PVS device (6-10 Fr) was applied in 930 patients with PAOD. All patients had received an endoluminal intervention in the pelvic and/or the contralateral femoropopliteal region via a retrograde access through the common femoral artery (CFA). The incidence of complications within 12 hr after intervention, prior to discharge, and at 30-day follow-up was assessed employing clinical examination, treadmill test, and color Doppler ultrasound and the safety of the PVS device was determined, The efficacy of the system was measured by the percentage of achieved immediate hemostasis and early ambulation. PVS was technically successful in 92.2% independently from the degree of calcification at the access site. In 7.8%, an appropriate suture delivery could not be performed and these patients were successfully treated by conventional compression technique. Device malfunction or insufficient suture closure occurred in 1.7% and 2.1%, respectively. In 7.0%, groin-related complications occurred. Ambulation within 2-4 hr after successful suture was possible in 96.1%. All patients were free of any local symptoms at 30-day follow-up. The PVS device provides a safe and effective solution to achieve immediate hemostasis, thus permitting early ambulation in fully anticoagulated patients with PAOD after peripheral interventional procedures. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:174 / 181
页数:8
相关论文
共 15 条
[1]   NONSURGICAL CLOSURE OF FEMORAL PSEUDOANEURYSMS COMPLICATING CARDIAC-CATHETERIZATION AND PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
AGRAWAL, SK ;
PINHEIRO, L ;
ROUBIN, GS ;
HEARN, JA ;
CANNON, AD ;
MACANDER, PJ ;
BARNES, JL ;
DEAN, LS ;
NANDA, NC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (03) :610-615
[2]   INCIDENCE AND RESULTS OF ARTERIAL COMPLICATIONS AMONG 16,350 PATIENTS UNDERGOING CARDIAC-CATHETERIZATION [J].
BABU, SC ;
PICCORELLI, GO ;
SHAH, PM ;
STEIN, JH ;
CLAUSS, RH .
JOURNAL OF VASCULAR SURGERY, 1989, 10 (02) :113-116
[3]  
Carere RG, 1996, CATHETER CARDIO DIAG, V37, P367, DOI 10.1002/(SICI)1097-0304(199604)37:4<367::AID-CCD5>3.0.CO
[4]  
2-9
[5]   POSTCATHETERIZATION FEMORAL-ARTERY INJURIES - IS THERE A ROLE FOR NONSURGICAL TREATMENT [J].
DORFMAN, GS ;
CRONAN, JJ .
RADIOLOGY, 1991, 178 (03) :629-630
[6]   Suture-mediated percutaneous closure of antegrade femoral arterial access sites in patients who have received full anticoagulation therapy [J].
Duda, SH ;
Wiskirchen, J ;
Erb, M ;
Schott, U ;
Khaligi, K ;
Pereira, PL ;
Albes, J ;
Claussen, CD .
RADIOLOGY, 1999, 210 (01) :47-52
[7]  
FLUECKIGER F, 1992, ACTA RADIOL, V33, P152
[8]  
FORAN JPM, 1993, BRIT HEART J, V69, P424
[9]   Percutaneous suturing of femoral artery access sites after diagnostic cardiac catheterization or coronary intervention [J].
Gerckens, U ;
Cattelaens, N ;
Muller, R ;
Lampe, EG ;
Grube, E .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1997, 6 (03) :217-220
[10]   Use of a collagen plug versus manual compression for sealing arterial puncture site after cardiac catheterization [J].
Gwechenberger, M ;
Katzenschlager, R ;
Heinz, G ;
GottsaunerWolf, M ;
Probst, P .
ANGIOLOGY, 1997, 48 (02) :121-126