Portable urea biosensor based on the extended-gate field effect transistor

被引:142
作者
Chen, JC
Chou, JC [1 ]
Sun, TP
Hsiung, SK
机构
[1] Natl Yunlin Univ Sci & Technol, Inst Elect & Informat Engn, Touliu 640, Taiwan
[2] Chung Yuan Christian Univ, Inst Elect Engn, Chungli 320, Taiwan
关键词
extended-gate FET; urea; SnO2; portable; disposable; PVA-SbQ;
D O I
10.1016/S0925-4005(03)00161-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, extended-gate field effect transistor (EGFET) was applied to fabricate disposable urea biosensor. And the 1.5 V low-voltage instrument amplifier was adopted to realize the portable urea biosensor. However, the difference between extended-gate field effect transistor and traditional ion-selective field effect transistor is the position of the sensitive membrane. The extended-gate field effect transistor was separated into two parts, which are the sensitive membrane and MOSFET. Hence, the MOSFET device can be designed to be a part of the readout circuit and the sensitive membrane was only put in the solution. Therefore, the configuration of the extended-gate field effect transistor can reduce the influence of the temperature, light and the erosion by the solutions. Besides, the configuration can reduce the cost substantially. The configuration of the extended-gate field effect transistor will raise the competitiveness to develop the disposable biosensor. The content of the urea in blood is one of the indexes to diagnose the renal efficiency. Then, the portable urea biosensor is the important expandable aspect. In this study, the gels, which are the poly vinyl alcohol with pendent styrylpyridinium groups, were used to immobilize the urease. The detection of the urea is based on the variation of pH value. Then, the dynamic range of the urea biosensor is from 0.31 to 120 mg/dl at the 5 mM phosphate buffer solution and the response time is about 2 min. 2003 Published by Elsevier Science B.V.
引用
收藏
页码:180 / 186
页数:7
相关论文
共 16 条
  • [1] Bahmani F, 2000, ISCAS 2000: IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS - PROCEEDINGS, VOL II, P669, DOI 10.1109/ISCAS.2000.856417
  • [2] Designing 1-V OP amps using standard digital CMOS technology
    Blalock, BJ
    Allen, PE
    Rincon-Mora, GA
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-ANALOG AND DIGITAL SIGNAL PROCESSING, 1998, 45 (07): : 769 - 780
  • [3] DETERMINATION OF UREA IN BLOOD-SERUM BY A UREASE BIOSENSOR BASED ON AN ION-SENSITIVE FIELD-EFFECT TRANSISTOR
    BOUBRIAK, OA
    SOLDATKIN, AP
    STARODUB, NF
    SANDROVSKY, AK
    ELSKAYA, AK
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1995, 27 (1-3) : 429 - 431
  • [4] FIELD-EFFECT TRANSISTOR SENSITIVE TO PENICILLIN
    CARAS, S
    JANATA, J
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (12) : 1935 - 1937
  • [5] Study on extended gate field effect transistor with tin oxide sensing membrane
    Chi, LL
    Chou, JC
    Chung, WY
    Sun, TP
    Hsiung, SK
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2000, 63 (01) : 19 - 23
  • [6] CHOU JC, 2001, Patent No. 6218208
  • [7] Design of a low-voltage instrumentation amplifier for Enzyme-Extended-Gate Field Effect Transistor based urea sensor application
    Chung, WY
    Yeh, MH
    Chen, JC
    Hsiung, SK
    Pijanowska, DG
    Torbicz, W
    Chou, JC
    Sun, TP
    [J]. FIRST IEEE INTERNATION WORKSHOP ON ELECTRONIC DESIGN, TEST AND APPLICATIONS, PROCEEDINGS, 2002, : 177 - 180
  • [8] HSIUNG SK, 2001, Patent No. 6236075
  • [9] Semiconductor-based micro-biosensors
    Jaffrezic-Renault, N
    Martelet, C
    [J]. SYNTHETIC METALS, 1997, 90 (03) : 205 - 210
  • [10] Use of photopolymerizable membranes based on polyacrylamide hydrogels for enzymatic microsensor construction
    Jimenez, C
    Bartrol, J
    deRooij, NF
    KoudelkaHep, M
    [J]. ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) : 169 - 176