Energy conservation and retrofitting potential in Hellenic hotels

被引:96
作者
Santamouris, M
Balaras, CA
Dascalaki, E
Argiriou, A
Gaglia, A
机构
[1] Group Building Environmental Studies, Department of Applied Physics, University of Athens, GR 106 80 Athens
[2] Group Energy Conservation, IMPAE, National Observatory of Athens, GR 118 10 Athens
关键词
energy conservation; retrofitting potential; Hellenic hotels;
D O I
10.1016/0378-7788(95)00963-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Energy consumption data from 158 Hellenic hotels and estimated energy savings that result from the use of practical retrofitting techniques, materials and new energy efficient systems are presented. The data were collected during an extensive energy audit of buildings that was carried out in Hellas, within the frame of a National Energy Programme sponsored by the CECVALORENProgramme, for energy conservation in buildings. During this short monitoring campaign and on-site visits of a trained panel of engineers to each building, all information related to the building's construction, heating, cooling and lighting systems, and all other mechanical and electrical systems, was collected. The main results and energy characteristics of cooling, heating and lighting on energy consumption and performance are discussed. The annual average total energy consumption in hotels is 273 kWh/m(2), one of the highest among all categories of buildings. Several scenarios for possible interventions to the building's outer envelope, heating, cooling and lighting systems are proposed and evaluated, in order to assess the effectiveness of various energy conservation techniques. Based on the results from several simulations, it is concluded that it is possible to reach an overall 20% energy conservation.
引用
收藏
页码:65 / 75
页数:11
相关论文
共 16 条
[1]   ON THE USE OF THE ATMOSPHERIC HEAT SINKS FOR HEAT DISSIPATION [J].
AGAS, G ;
MATSAGGOS, T ;
SANTAMOURIS, M ;
ARGYRIOU, A .
ENERGY AND BUILDINGS, 1991, 17 (04) :321-329
[2]  
Antinucci M., 1992, International Journal of Solar Energy, V11, P251, DOI 10.1080/01425919208909744
[3]  
ANTINUCCI M, 1991, STATE ART PASSIVE CO
[4]  
BENYA J, 1989, PROG ARCHIT, V7, P230
[5]  
*EC NAT SUP MIN PA, 1988, DESCR MAN CASAMO CLI
[6]  
FLEURY B, 1990, NATURAL COOLING TECH
[7]  
GREEN C, 1991, SIMULATION TOOL SPIE
[8]  
PESCOD D, 1980, TELECOMMUN J AUST, V30, P2
[9]   ENERGY CHARACTERISTICS AND SAVINGS POTENTIAL IN OFFICE BUILDINGS [J].
SANTAMOURIS, M ;
ARGIRIOU, A ;
DASCALAKI, E ;
BALARAS, C ;
GAGLIA, A .
SOLAR ENERGY, 1994, 52 (01) :59-66
[10]   ENERGY PERFORMANCE AND ENERGY-CONSERVATION IN HEALTH-CARE BUILDINGS IN HELLAS [J].
SANTAMOURIS, M ;
DASCALAKI, E ;
BALARAS, C ;
ARGIRIOU, A ;
GAGLIA, A .
ENERGY CONVERSION AND MANAGEMENT, 1994, 35 (04) :293-305