Inadequacy of low-volume resuscitation with hemoglobin-based oxygen carrier hemoglobin glutamer-200 (bovine) in canine hypovolemia

被引:34
作者
Driessen, B
Jahr, JS
Lurie, F
Gunther, RA
机构
[1] Univ Penn, New Bolton Ctr, Sch Vet Med, Dept Clin Studies, Kennett Sq, PA 19348 USA
[2] Univ Calif Davis, Davis Med Ctr, Dept Anesthesiol & Pain Med, Davis, CA USA
[3] Univ Calif Davis, Davis Med Ctr, Dept Surg, Davis, CA USA
关键词
D O I
10.1046/j.1365-2885.2001.00307.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Stroma-free hemoglobin-based oxygen carriers (HBOC) have been developed to overcome problems associated with transfusion of allogeneic blood. We have studied the efficacy of the first licensed veterinary blood substitute, hemoglobin glutamer-200 bovine (Oxyglobin(R); Biopure, Cambridge, MA, USA, Hb-200), in a canine model of acute hypovolemia and examined whether clinically commonly used criteria are adequate to guide fluid resuscitation with this product. Twelve anesthetized dogs were instrumented for measurements of physiological variables including hemodynamic, oxygenation, and blood gas and acid-base parameters. Dogs were bled to a mean arterial pressure (MAP) of 50 mmHg for 1 h followed by resuscitation with either shed blood (controls) or Hb-200 until heart rate (HR), MAP and central venous pressure (CVP) returned to baseline. Recordings were repeated immediately and 3 h after termination of fluid resuscitation. Hemorrhage (average 32 mL/kg) caused significant decreases in total hemoglobin (Hb), mean pulmonary arterial pressure (PAP), cardiac output (CO) and oxygen delivery (DO2I), increases in HR and systemic vascular resistance (SVRI), and lactic acidosis. In controls, only re-transfusion of an shed blood returned HR, MAP and CVP to prehemorrhage values, whereas in other dogs this endpoint was reached with infusion of 10 mL/kg Hb-200. Unlike blood transfusion, Hb-200 infusion failed to return CI and DO2I to baseline and to increase arterial oxygen content (CaO2) and total Hb; SVRI further increased. Thus, commonly used criteria (HR, MAP, CVP) to guide transfusion therapy in patients posthemorrhage prove insufficient when HBOCs with pronounced vasoconstrictive action are used and lead to inadequate volume repletion.
引用
收藏
页码:61 / 71
页数:11
相关论文
共 52 条
[1]   Effect of human hemoglobin on systemic and regional hemodynamics in a porcine model of endotoxemic shock [J].
Aranow, JS ;
Wang, HL ;
Zhuang, J ;
Fink, MP .
CRITICAL CARE MEDICINE, 1996, 24 (05) :807-814
[2]  
BOSMAN RJ, 1992, ANESTH ANALG, V75, P811
[3]  
Botzlar A, 1996, Eur J Med Res, V1, P471
[4]   Transcranial Doppler sonography mean flow velocity during infusion of ultrapurified bovine hemoglobin [J].
Brauer, P ;
Standl, T ;
Wilhelm, S ;
Burmeister, MA ;
Esch, JSA .
JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1998, 10 (03) :146-152
[5]   Diaspirin cross-linked hemoglobin resuscitation improves cerebral perfusion after head injury and shock [J].
Chappell, JE ;
McBride, WJ ;
Shackford, SR .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 41 (05) :781-788
[6]  
deFigueiredo LFP, 1997, J TRAUMA, V42, P847
[7]   Haemodynamic effects of ATP in dogs during hypoxia-induced pulmonary hypertension [J].
Driessen, B ;
Haskins, SC ;
Pascoe, PJ ;
Tripp, LD ;
Reitan, JA .
JOURNAL OF VETERINARY PHARMACOLOGY AND THERAPEUTICS, 1999, 22 (03) :213-219
[8]   Fentanyl pharmacokinetics in hemorrhagic shock - A porcine model [J].
Egan, TD ;
Kuramkote, S ;
Gong, GQ ;
Zhang, J ;
McJames, SW ;
Bailey, PL .
ANESTHESIOLOGY, 1999, 91 (01) :156-166
[9]  
Faivre-Fiorina Beatrice, 1999, American Journal of Physiology, V276, pH766
[10]   Synchronization phase diagrams of monolithic colliding pulse-modelocked lasers [J].
Franck, T ;
Brorson, SD ;
MollerLarsen, A ;
Nielsen, JM ;
Mork, J .
IEEE PHOTONICS TECHNOLOGY LETTERS, 1996, 8 (01) :40-42