SIMPLISMA applied to two-dimensional wavelet compressed ion mobility spectrometry data

被引:21
作者
Chen, GX [1 ]
Harrington, PD [1 ]
机构
[1] Ohio Univ, Ctr Intelligent Chem Instrumentat, Dept Chem & Biochem, Athens, OH 45701 USA
关键词
multivariate curve resolution; SIMPLISMA; multidimensional wavelet compression; ion mobility spectrometry; drugs of abuse; bacteria;
D O I
10.1016/S0003-2670(03)00306-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A modified SIMPLe-to-use Interactive Self-modeling Mixture Analysis (SIMPLISMA) algorithm, referred to as real-time (RT) SIMPLISMA has been combined with two-dimensional (213) wavelet compression (WC2). This tool was evaluated with datasets of drugs and bacteria that were acquired from two different ion mobility spectrometers and published reference data that comprised Raman, FTIR microscopy, near-infrared (NIR) and mass spectral data. RTSIMPLISMA is amenable for real-time modeling and is able to determine the number of components automatically. The 2D wavelet compression, which compresses both acquisition and drift time dimensions of measurement, was applied to the datasets prior to RTSIMPLISMA modeling. RTSIMPLISMA models obtained from the compressed data were wavelet transformed back to the uncompressed representation. The effects of wavelet filter types and compression levels were investigated. The relative root-mean-square errors (RRMSE) of reconstruction, which calculate the relative difference between the extracted models with and without 2D compressions, were used to evaluate the effects of compression on self-modeling. The results showed that satisfactory models could be obtained when a data was compressed to 1/256 of its size. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:75 / 91
页数:17
相关论文
共 57 条
  • [1] Wavelet denoising of infrared spectra
    Alsberg, BK
    Woodward, AM
    Winson, MK
    Rowland, J
    Kell, DB
    [J]. ANALYST, 1997, 122 (07) : 645 - 652
  • [2] An introduction to wavelet transforms for chemometricians: A time-frequency approach
    Alsberg, BK
    Woodward, AM
    Kell, DB
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 37 (02) : 215 - 239
  • [3] Separation and identification of some chemical warfare degradation products using electrospray high resolution ion mobility spectrometry with mass selected detection
    Asbury, GR
    Wu, C
    Siems, WF
    Hill, HH
    [J]. ANALYTICA CHIMICA ACTA, 2000, 404 (02) : 273 - 283
  • [4] Asbury GR, 2000, TALANTA, V50, P1291
  • [5] Rapid multivariate curve resolution applied to identification of explosives by ion mobility spectrometry
    Buxton, TL
    Harrington, PD
    [J]. ANALYTICA CHIMICA ACTA, 2001, 434 (02) : 269 - 282
  • [6] BUXTON TL, 2002, THESIS OHIO U ATHENS
  • [7] Wavelet transform preprocessing for temperature constrained cascade correlation neural networks
    Cai, C
    Harrington, PD
    [J]. JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 1999, 39 (05): : 874 - 880
  • [8] Two-dimensional Fourier compression
    Cai, CS
    Harrington, PD
    Davis, DM
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (20) : 4249 - 4255
  • [9] Compression of infrared spectral data using the fast wavelet transform method
    Chau, FT
    Gao, JB
    Shih, TM
    Wang, J
    [J]. APPLIED SPECTROSCOPY, 1997, 51 (05) : 649 - 659
  • [10] Real-time interactive self-modeling mixture analysis
    Chen, G
    Harrington, PB
    [J]. APPLIED SPECTROSCOPY, 2001, 55 (05) : 621 - 629