Film cooling from shaped holes

被引:184
作者
Bell, CM
Hamakawa, H
Ligrani, PM [1 ]
机构
[1] Univ Utah, Dept Mech Engn, Convect Heat Transfer Lab, Salt Lake City, UT 84112 USA
[2] Oita Univ, Oita 87011, Japan
来源
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME | 2000年 / 122卷 / 02期
关键词
engines; film cooling; flow; heat transfer; turbines;
D O I
10.1115/1.521484
中图分类号
O414.1 [热力学];
学科分类号
摘要
Local and spatially averaged magnitudes of the adiabatic film cooling effectiveness, the iso-energetic Stanton number ratio, and film cooling performance parameter are measured downstream of (i) cylindrical round, simple angle (CYSA) holes, (ii) laterally diffused, simple angle (LDSA) holes, (iii) laterally diffused, compound angle (LDCA) holes, (iv) forward diffused, simple angle (FDSA( holes, and (v) forward diffused, compound angle (FDCA) holes. Data are presented for length-to-inlet metering diameter ratio of 3, blowing ratios from 0.4 to 1.8, momentum flux ratios from 0.17 to 3.5, and density ratios from 0.9 to 1.4. The LDCA and FDCA arrangements produce higher effectiveness magnitudes over much wider ranges of flowing ratio and momentum flux ratio compared to the three simple angle configurations tested. All three simple angle hole geometries, CYSA, FDSA, and LDSA, show increases of spanwise-averaged adiabatic effectiveness as the density ratio increases from 0.9 to 1.4, which are larger than changes measured downstream of FDCA and LDCA holes. Iso-energetic Stanton number ratios downstream of LDCA and FDCA holes (measured with unity density ratios) are generally increased relative to simple angle geometries for m greater than or equal to1.0 when compared at particular normalized streamwise locations, x/D, and blowing ratios, m. Even though this contributes to higher performance parameters and low protection, overall film cooling performance parameter (q) over dot "/(q) over dot(o)" variations with x/D and m are qualitatively similar to variations of adiabatic film cooling effectiveness with x/D and m. Consequently, the best overall protection over the widest ranges of blowing ratios, momentum flux ratios, and streamwise locations is provided by LDCA holes, followed by FDCA holes. Such improvements in protection are partly due to film diffusion from expanded hole shapes, as well as increased lateral spreading fo injectant from compound angles.
引用
收藏
页码:224 / 232
页数:9
相关论文
共 26 条
[1]  
AJERSCH P, 1995, INT GAS TURB AER C E
[2]  
[Anonymous], INT GAS TURB AER C E
[3]  
[Anonymous], 1953, MECH ENG
[4]  
BELL CM, 1998, THESIS U UTAH SALT L
[5]  
BERGER PA, 1998, INT GAS TURB AER C E
[6]  
BRITTINGHAM RA, 1997, INT GAS TURB AER C E
[7]  
CHEN PH, 1998, INT GAS TURB AER C E
[8]  
ERIKSEN VL, 1974, ASME, V96, P239
[9]  
FARMER JP, 1997, INT GAS TURB AER C E
[10]  
GIEBERT D, 1997, INT GAS TURB AER C E