Ambient formaldehyde detection with a laser spectrometer based on difference-frequency generation in PPLN

被引:69
作者
Rehle, D
Leleux, D
Erdelyi, M
Tittel, F
Fraser, M
Friedfeld, S
机构
[1] Rice Univ, Dept Elect & Comp Engn, Houston, TX 77251 USA
[2] Rice Univ, Dept Environm Sci & Engn, Houston, TX 77251 USA
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2001年 / 72卷 / 08期
关键词
D O I
10.1007/s003400100549
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A laser spectrometer based on difference-frequency generation in periodically poled LiNbO3 (PPLN) has been used to quantify atmospheric formaldehyde with a detection limit of 0.32 parts per billion in a given volume (ppbV) using specifically developed data-processing techniques. With state-of-the-art fiber-coupled diode-laser pump sources at 1083 nm and 1561 nm, difference-frequency radiation has been generated in the 3.53-mum (2832-cm(-1)) spectral region. Formaldehyde in ambient air in the 1- to 10-ppb V range has been detected continuously for nine and five days at two separate field sites in the Greater Houston area operated by the Texas Natural Resource Conservation Commission (TNRCC) and the Houston Regional Monitoring Corporation (HRM). The acquired spectroscopic data are compared with results obtained by a well-established wet-chemical 0-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA) technique.
引用
收藏
页码:947 / 952
页数:6
相关论文
共 27 条
[1]  
BRASSINGTON DJ, 1995, SPECTROSCOPY ENV SCI
[2]   CONTINUOUS-WAVE INFRARED-LASER SPECTROMETER BASED ON DIFFERENCE-FREQUENCY-GENERATION IN AGGAS2 FOR HIGH-RESOLUTION SPECTROSCOPY [J].
CANARELLI, P ;
BENKO, Z ;
CURL, R ;
TITTEL, FK .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1992, 9 (02) :197-202
[3]  
CARTER WPL, 1994, J AIR WASTE MANAGE, V44, P881
[4]   CONTINUOUS LIQUID-PHASE FLUOROMETRY COUPLED TO A DIFFUSION SCRUBBER FOR THE REAL-TIME DETERMINATION OF ATMOSPHERIC FORMALDEHYDE, HYDROGEN-PEROXIDE AND SULFUR-DIOXIDE [J].
DASGUPTA, PK ;
DONG, S ;
HWANG, H ;
YANG, HC ;
GENFA, Z .
ATMOSPHERIC ENVIRONMENT, 1988, 22 (05) :949-963
[5]   Air quality model evaluation data for organics .1. Bulk chemical composition and gas/particle distribution factors [J].
Fraser, MP ;
Grosjean, D ;
Grosjean, E ;
Rasmussen, RA ;
Cass, GR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (05) :1731-1743
[6]   Laboratory, ground-based, and airborne tunable diode laser systems: performance characteristics and applications in atmospheric studies [J].
Fried, A ;
Henry, B ;
Wert, B ;
Sewell, S ;
Drummond, JR .
APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 67 (03) :317-330
[7]   Tunable diode laser absorption spectrometer for ground-based measurements of formaldehyde [J].
Fried, A ;
Sewell, S ;
Henry, B ;
Wert, BP ;
Gilpin, T ;
Drummond, JR .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1997, 102 (D5) :6253-6266
[8]  
FRIEDFELDT S, 2000, GEOPHYS RES LETT, V27, P2903
[9]   Intercomparison of six ambient [CH2O] measurement techniques [J].
Gilpin, T ;
Apel, E ;
Fried, A ;
Wert, B ;
Calvert, J ;
Zhang, GF ;
Dasgupta, PK ;
Harder, JW ;
Heikes, B ;
Hopkins, B ;
Westberg, H ;
Kleindienst, T ;
Lee, YN ;
Zhou, XL ;
Lonneman, W ;
Sewell, S .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1997, 102 (D17) :21161-21188
[10]   Highly efficient 4-W Yb-doped fiber amplifier pumped by a broad-stripe laser diode [J].
Goldberg, L ;
Koplow, JP ;
Kliner, DAV .
OPTICS LETTERS, 1999, 24 (10) :673-675