Quantitative analysis of palm carotene using Fourier transform infrared and near infrared spectroscopy

被引:36
作者
Moh, MH
Man, YBC [1 ]
Badlishah, BS
Jinap, S
Saad, MS
Abdullah, WJW
机构
[1] Univ Pertanian Malaysia, Fac Food Sci & Biotechnol, Dept Food Technol, Serdang 43400, Selangor, Malaysia
[2] Univ Pertanian Malaysia, Fac Food Sci & Biotechnol, Dept Biotechnol, Serdang 43400, Selangor, Malaysia
[3] Univ Pertanian Malaysia, Fac Food Sci & Biotechnol, Dept Food Sci, Serdang 43400, Selangor, Malaysia
关键词
beta-carotene; FTIR; NIR; palm oil; spectroscopy;
D O I
10.1007/s11746-999-0226-9
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
beta-carotene content is usually determined by using ultraviolet (UV)-visible spectrophotometry at 446 nm. In this study, two spectroscopic techniques, namely, Fourier transform infrared (FTIR) and near infrared (NIR) spectroscopy, have been investigated and compared to UV-visible spectrophotometry to measure the beta-carotene content of crude palm oil (CPO). Calibration curves ranging from 200 to 800 ppm were prepared by extracting beta-carotene from original CPO using open-column chromatography. Separate partial least squares calibration models were developed for predicting beta-carotene based on the spectral region from 976 to 926 cm(-1) for FTIR spectroscopy and 546 to 819 nm for NIR spectroscopy. The correlation coefficient (R-2) and standard error of calibration obtained were 0.972 and 25.2 for FTIR and 0.952 and 23.6 for NIR techniques, respectively. The validation set gave R-2 of 0.951 with standard error of performance (SEP) of 25.78 for FTIR technique and R-2 of 0.979 with SEP of 19.96 for NIR technique. The overall reproducibility and accuracy did not give comparable results to that of spectrophotometric method; however, the standard deviation of prediction was still within +/- 5% beta-carotene content over the range tested. Because of their rapidness and simplicity, both FTIR and NIR techniques provide alternative means of measuring beta-carotene content in CPO. In addition, these two spectroscopic techniques are environmentally friendly since no solvent is involved.
引用
收藏
页码:249 / 254
页数:6
相关论文
共 24 条
[1]  
ALAM B S, 1987, Nutrition and Cancer, V9, P93
[2]  
BUDZIKIEWICZ H, 1982, CAROTENOID CHEM BIOC, P155
[3]  
DOLPHIN D, 1977, TABULATION INFRARED, P22
[4]  
ENGLERT G, 1982, CAROTENOID CHEM BIOC, P107
[5]  
Guillen MD, 1997, J SCI FOOD AGR, V75, P1, DOI [10.1002/(SICI)1097-0010(199709)75:1<1::AID-JSFA842>3.0.CO
[6]  
2-R, 10.1002/(SICI)1097-0010(199709)75:1&lt
[7]  
1::AID-JSFA842&gt
[8]  
3.0.CO
[9]  
2-R]
[10]   NEAR-INFRARED SPECTRA OF FATTY ACIDS AND SOME RELATED SUBSTANCES [J].
HOLMAN, RT ;
EDMONDSON, PR .
ANALYTICAL CHEMISTRY, 1956, 28 (10) :1533-1538