Analysis of acrylamide in food by isotope-dilution liquid chromatography coupled with electrospray ionization tandem mass spectrometry

被引:95
作者
Riediker, S [1 ]
Stadler, RH [1 ]
机构
[1] Nestle SA, Nestle Res Ctr, CH-1000 Lausanne 26, Switzerland
关键词
food analysis; cereals; interlaboratory test; validation; isotope dilution methods; acrylamide;
D O I
10.1016/S0021-9673(03)00876-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A confirmatory method for the determination of low levels of acrylamide in different food products is presented. The method entails extraction of acrylamide with water, precipitation of matrix constituents with acetonitrile, and two clean-up steps consecutively over Isolute Multimode and cation-exchange cartridges. The final extract is analyzed by liquid chromatography (LC) coupled to positive electrospray ionization tandem mass spectrometry employing [C-13(3)-acrylamide as internal standard. For the chromatographic step, a LC column based on a polymethacrylate gel is employed which shows good retention of acrylamide under isocratic flow conditions (k' = 1.2). Mass spectral acquisition is done by selected reaction monitoring, choosing the characteristic transitions m/z 72-->55, 72-->54 and 72-->27. In-house validation data for breakfast cereals and crackers show good precision of the method, with intra- and interassay variation below 10%. The limits of detection for crackers and breakfast cereals, respectively are estimated at 15 and 20 mug/kg, and recoveries of fortified samples ranged between 58 and 76%. Furthermore, the method is applicable to a number of different food products, including biscuits, crisp bread, wafers, confectionery cocoa liquor, and nuts. Finally, the good results obtained in several small-scale interlaboratory tests provided additional confidence in the performance of the method. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 130
页数:10
相关论文
共 26 条
[1]   Verification of the findings of acrylamide in heated foods [J].
Ahn, JS ;
Castle, L ;
Clarke, DB ;
Lloyd, AS ;
Philo, MR ;
Speck, DR .
FOOD ADDITIVES AND CONTAMINANTS, 2002, 19 (12) :1116-1124
[2]  
[Anonymous], 2002, OFF J EUR COMMUNIT L, VL221
[3]  
[Anonymous], 2002, INF ACR FOOD
[4]   Determination of acrylamide and glycidamide in rat plasma by reversed-phase high performance liquid chromatography [J].
Barber, DS ;
Hunt, J ;
LoPachin, RM ;
Ehrich, M .
JOURNAL OF CHROMATOGRAPHY B, 2001, 758 (02) :289-293
[5]   Acrylamide in foods: Occurrence, sources, and modeling [J].
Becalski, A ;
Lau, BPY ;
Lewis, D ;
Seaman, SW .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (03) :802-808
[6]  
Biedermann Maurus, 2002, Mitteilungen aus Lebensmitteluntersuchung und Hygiene, V93, P638
[7]   Analysis of residual acrylamide in field crops [J].
Bologna, LS ;
Andrawes, FF ;
Barvenik, FW ;
Lentz, RD ;
Sojka, RE .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1999, 37 (07) :240-244
[8]   DETERMINATION OF ACRYLAMIDE MONOMER IN MUSHROOMS GROWN ON POLYACRYLAMIDE-GEL [J].
CASTLE, L .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1993, 41 (08) :1261-1263
[9]  
Clarke DB, 2002, J AOAC INT, V85, P1370
[10]  
Gertz C, 2002, EUR J LIPID SCI TECH, V104, P762, DOI 10.1002/1438-9312(200211)104:11<762::AID-EJLT762>3.0.CO