Abnormal septal motion affects early diastolic velocities at the septal and lateral mitral annulus, and impacts on estimation of the pulmonary capillary wedge pressure

被引:42
作者
D'Souza, KA
Mooney, DJ
Russell, AE
MacIsaac, AL
Aylward, PE
Prior, DL
机构
[1] St Vincents Hosp, Dept Cardiol, Fitzroy, Vic 3065, Australia
[2] Flinders Med Ctr, Bedford Pk, SA, Australia
基金
英国医学研究理事会;
关键词
D O I
10.1016/j.echo.2005.01.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Abnormal motion of the interventricular septum (ASM), seen post cardiac operation, with left bundle branch block or right ventricular pacing, may affect septal mitral annular motion and correlation of the ratio between the velocity of early diastolic mitral inflow and the early diastolic mitral annular velocity (E/Ea) with pulmonary capillary wedge pressure (PCWP). We examined the effect of ASM on the relationship between E/Ea and E/Vp (propagation velocity of mitral inflow) ratios and PCWP in adult patients in the intensive care unit (14 with normal septal motion [NSM], 36 with ASM) undergoing echocardiography and pulmonary artery catheterization. E/Ea correlated well with PCWP during NSM (r = 0.86 lateral annulus, r = 0.75 septal annulus), but poorly during ASM (r 0.36 lateral annulus, r = 0.39 septal annulus). E/Vp correlated poorly with PCWP (r = 0.05 NSM, r = 0.17 ASM). For patients who are critically ill, E/Vp ratios poorly estimate PCWP. During NSM, E/Ea ratios measured at the lateral or septal annulus correlate well with PCWP. ASM affects E/Ea ratios at both the septal and lateral annulus, making E/Ea ratios unreliable for estimating PCWP in this group.
引用
收藏
页码:445 / 453
页数:9
相关论文
共 30 条
  • [1] CLINICAL, RADIOGRAPHIC, AND HEMODYNAMIC CORRELATIONS IN CHRONIC CONGESTIVE-HEART-FAILURE - CONFLICTING RESULTS MAY LEAD TO INAPPROPRIATE CARE
    CHAKKO, S
    WOSKA, D
    MARTINEZ, H
    DEMARCHENA, E
    FUTTERMAN, L
    KESSLER, KM
    MYERBURG, RJ
    [J]. AMERICAN JOURNAL OF MEDICINE, 1991, 90 (03) : 353 - 359
  • [2] ECHOCARDIOGRAPHIC MANIFESTATIONS OF LEFT-BUNDLE BRANCH-BLOCK
    DILLON, JC
    CHANG, S
    FEIGENBAUM, H
    [J]. CIRCULATION, 1974, 49 (05) : 876 - 880
  • [3] Does positive end-expiratory pressure ventilation improve left ventricular function? A comparative study by transesophageal echocardiography in cardiac and noncardiac patients
    Fellahi, JL
    Valtier, B
    Beauchet, A
    Bourdarias, JP
    Jardin, F
    [J]. CHEST, 1998, 114 (02) : 556 - 562
  • [4] MECHANISMS OF THE DEVELOPMENT AND RESOLUTION OF PARADOXICAL INTERVENTRICULAR SEPTAL MOTION AFTER UNCOMPLICATED CARDIAC-SURGERY
    FENELEY, M
    KEARNEY, L
    FARNSWORTH, A
    SHANAHAN, M
    CHANG, V
    [J]. AMERICAN HEART JOURNAL, 1987, 114 (01) : 106 - 114
  • [5] Differentiation of constrictive pericarditis from restrictive cardiomyopathy: Assessment of left ventricular diastolic velocities in longitudinal axis by Doppler tissue imaging
    Garcia, MJ
    Rodriguez, L
    Ares, M
    Griffin, BP
    Thomas, JD
    Klein, AL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (01) : 108 - 114
  • [6] An index of early left ventricular filling that combined with pulsed Doppler peak E velocity may estimate capillary wedge pressure
    Garcia, MJ
    Ares, MA
    Asher, C
    Rodriguez, L
    Vandervoort, P
    Thomas, JD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 448 - 454
  • [7] FUNCTIONAL ABNORMALITIES IN ISOLATED LEFT-BUNDLE BRANCH-BLOCK - THE EFFECT OF INTERVENTRICULAR ASYNCHRONY
    GRINES, CL
    BASHORE, TM
    BOUDOULAS, H
    OLSON, S
    SHAFER, P
    WOOLEY, CF
    [J]. CIRCULATION, 1989, 79 (04) : 845 - 853
  • [8] The incidence of major morbidity in critically ill patients managed with pulmonary artery catheters: A meta-analysis
    Ivanov, R
    Allen, J
    Calvin, JE
    [J]. CRITICAL CARE MEDICINE, 2000, 28 (03) : 615 - 619
  • [9] INFLUENCE OF POSITIVE END-EXPIRATORY PRESSURE ON LEFT-VENTRICULAR PERFORMANCE
    JARDIN, F
    FARCOT, JC
    BOISANTE, L
    CURIEN, N
    MARGAIRAZ, A
    BOURDARIAS, JP
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1981, 304 (07) : 387 - 392
  • [10] Insertion time of the pulmonary artery catheter in critically ill patients
    Lefrant, JY
    Muller, L
    Bruelle, P
    Pandolfi, JL
    L'Hermite, J
    Peray, P
    Saïssi, G
    de La Coussaye, JE
    Eledjam, JJ
    [J]. CRITICAL CARE MEDICINE, 2000, 28 (02) : 355 - 359